mirror of https://gitee.com/openkylin/linux.git
98cbe371fd
[Resend patch as per Bernd Schubert comment ] Issue: Device goes offline while doing aggressive HBA reset along with IO using some utility. Root cause: FW goes into bad state due to aggressive reset. Softreset does not help to recover FW. And also aggressive reset open up the window for Error handling thread to kicked off at the same time HBA will be in constant RESET loop as part of aggressive reset test case can lead Device to goes offline. Changes: 1. Added extra check as below inside eh_timed_out call back as below. if(ioc->ioc_reset_in_progress) Rc = EH_TIMER_RESET 2. Removed " DOORBELL_ACTIVE" check for SAS controller from task management context. Since SAS controller uses high priority queue for task management. This check is not required for SAS controller. 3. Moved SoftReset call to HardReset from Task Mgmt context. Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com> Signed-off-by: James Bottomley <JBottomley@Parallels.com> |
||
---|---|---|
.. | ||
fusion | ||
i2o | ||
Makefile |