mirror of https://gitee.com/openkylin/linux.git
344 lines
11 KiB
Plaintext
344 lines
11 KiB
Plaintext
#
|
|
# Intel network device configuration
|
|
#
|
|
|
|
config NET_VENDOR_INTEL
|
|
bool "Intel devices"
|
|
default y
|
|
---help---
|
|
If you have a network (Ethernet) card belonging to this class, say Y.
|
|
|
|
Note that the answer to this question doesn't directly affect the
|
|
kernel: saying N will just cause the configurator to skip all
|
|
the questions about Intel cards. If you say Y, you will be asked for
|
|
your specific card in the following questions.
|
|
|
|
if NET_VENDOR_INTEL
|
|
|
|
config E100
|
|
tristate "Intel(R) PRO/100+ support"
|
|
depends on PCI
|
|
select MII
|
|
---help---
|
|
This driver supports Intel(R) PRO/100 family of adapters.
|
|
To verify that your adapter is supported, find the board ID number
|
|
on the adapter. Look for a label that has a barcode and a number
|
|
in the format 123456-001 (six digits hyphen three digits).
|
|
|
|
Use the above information and the Adapter & Driver ID Guide that
|
|
can be located at:
|
|
|
|
<http://support.intel.com>
|
|
|
|
to identify the adapter.
|
|
|
|
More specific information on configuring the driver is in
|
|
<file:Documentation/networking/device_drivers/intel/e100.rst>.
|
|
|
|
To compile this driver as a module, choose M here. The module
|
|
will be called e100.
|
|
|
|
config E1000
|
|
tristate "Intel(R) PRO/1000 Gigabit Ethernet support"
|
|
depends on PCI
|
|
---help---
|
|
This driver supports Intel(R) PRO/1000 gigabit ethernet family of
|
|
adapters. For more information on how to identify your adapter, go
|
|
to the Adapter & Driver ID Guide that can be located at:
|
|
|
|
<http://support.intel.com>
|
|
|
|
More specific information on configuring the driver is in
|
|
<file:Documentation/networking/device_drivers/intel/e1000.rst>.
|
|
|
|
To compile this driver as a module, choose M here. The module
|
|
will be called e1000.
|
|
|
|
config E1000E
|
|
tristate "Intel(R) PRO/1000 PCI-Express Gigabit Ethernet support"
|
|
depends on PCI && (!SPARC32 || BROKEN)
|
|
select CRC32
|
|
imply PTP_1588_CLOCK
|
|
---help---
|
|
This driver supports the PCI-Express Intel(R) PRO/1000 gigabit
|
|
ethernet family of adapters. For PCI or PCI-X e1000 adapters,
|
|
use the regular e1000 driver For more information on how to
|
|
identify your adapter, go to the Adapter & Driver ID Guide that
|
|
can be located at:
|
|
|
|
<http://support.intel.com>
|
|
|
|
More specific information on configuring the driver is in
|
|
<file:Documentation/networking/device_drivers/intel/e1000e.rst>.
|
|
|
|
To compile this driver as a module, choose M here. The module
|
|
will be called e1000e.
|
|
|
|
config E1000E_HWTS
|
|
bool "Support HW cross-timestamp on PCH devices"
|
|
default y
|
|
depends on E1000E && X86
|
|
---help---
|
|
Say Y to enable hardware supported cross-timestamping on PCH
|
|
devices. The cross-timestamp is available through the PTP clock
|
|
driver precise cross-timestamp ioctl (PTP_SYS_OFFSET_PRECISE).
|
|
|
|
config IGB
|
|
tristate "Intel(R) 82575/82576 PCI-Express Gigabit Ethernet support"
|
|
depends on PCI
|
|
imply PTP_1588_CLOCK
|
|
select I2C
|
|
select I2C_ALGOBIT
|
|
---help---
|
|
This driver supports Intel(R) 82575/82576 gigabit ethernet family of
|
|
adapters. For more information on how to identify your adapter, go
|
|
to the Adapter & Driver ID Guide that can be located at:
|
|
|
|
<http://support.intel.com>
|
|
|
|
More specific information on configuring the driver is in
|
|
<file:Documentation/networking/device_drivers/intel/igb.rst>.
|
|
|
|
To compile this driver as a module, choose M here. The module
|
|
will be called igb.
|
|
|
|
config IGB_HWMON
|
|
bool "Intel(R) PCI-Express Gigabit adapters HWMON support"
|
|
default y
|
|
depends on IGB && HWMON && !(IGB=y && HWMON=m)
|
|
---help---
|
|
Say Y if you want to expose thermal sensor data on Intel devices.
|
|
|
|
Some of our devices contain thermal sensors, both external and internal.
|
|
This data is available via the hwmon sysfs interface and exposes
|
|
the onboard sensors.
|
|
|
|
config IGB_DCA
|
|
bool "Direct Cache Access (DCA) Support"
|
|
default y
|
|
depends on IGB && DCA && !(IGB=y && DCA=m)
|
|
---help---
|
|
Say Y here if you want to use Direct Cache Access (DCA) in the
|
|
driver. DCA is a method for warming the CPU cache before data
|
|
is used, with the intent of lessening the impact of cache misses.
|
|
|
|
config IGBVF
|
|
tristate "Intel(R) 82576 Virtual Function Ethernet support"
|
|
depends on PCI
|
|
---help---
|
|
This driver supports Intel(R) 82576 virtual functions. For more
|
|
information on how to identify your adapter, go to the Adapter &
|
|
Driver ID Guide that can be located at:
|
|
|
|
<http://support.intel.com>
|
|
|
|
More specific information on configuring the driver is in
|
|
<file:Documentation/networking/device_drivers/intel/igbvf.rst>.
|
|
|
|
To compile this driver as a module, choose M here. The module
|
|
will be called igbvf.
|
|
|
|
config IXGB
|
|
tristate "Intel(R) PRO/10GbE support"
|
|
depends on PCI
|
|
---help---
|
|
This driver supports Intel(R) PRO/10GbE family of adapters for
|
|
PCI-X type cards. For PCI-E type cards, use the "ixgbe" driver
|
|
instead. For more information on how to identify your adapter, go
|
|
to the Adapter & Driver ID Guide that can be located at:
|
|
|
|
<http://support.intel.com>
|
|
|
|
More specific information on configuring the driver is in
|
|
<file:Documentation/networking/device_drivers/intel/ixgb.rst>.
|
|
|
|
To compile this driver as a module, choose M here. The module
|
|
will be called ixgb.
|
|
|
|
config IXGBE
|
|
tristate "Intel(R) 10GbE PCI Express adapters support"
|
|
depends on PCI
|
|
select MDIO
|
|
select MDIO_DEVICE
|
|
imply PTP_1588_CLOCK
|
|
---help---
|
|
This driver supports Intel(R) 10GbE PCI Express family of
|
|
adapters. For more information on how to identify your adapter, go
|
|
to the Adapter & Driver ID Guide that can be located at:
|
|
|
|
<http://support.intel.com>
|
|
|
|
More specific information on configuring the driver is in
|
|
<file:Documentation/networking/device_drivers/intel/ixgbe.rst>.
|
|
|
|
To compile this driver as a module, choose M here. The module
|
|
will be called ixgbe.
|
|
|
|
config IXGBE_HWMON
|
|
bool "Intel(R) 10GbE PCI Express adapters HWMON support"
|
|
default y
|
|
depends on IXGBE && HWMON && !(IXGBE=y && HWMON=m)
|
|
---help---
|
|
Say Y if you want to expose the thermal sensor data on some of
|
|
our cards, via a hwmon sysfs interface.
|
|
|
|
config IXGBE_DCA
|
|
bool "Direct Cache Access (DCA) Support"
|
|
default y
|
|
depends on IXGBE && DCA && !(IXGBE=y && DCA=m)
|
|
---help---
|
|
Say Y here if you want to use Direct Cache Access (DCA) in the
|
|
driver. DCA is a method for warming the CPU cache before data
|
|
is used, with the intent of lessening the impact of cache misses.
|
|
|
|
config IXGBE_DCB
|
|
bool "Data Center Bridging (DCB) Support"
|
|
default n
|
|
depends on IXGBE && DCB
|
|
---help---
|
|
Say Y here if you want to use Data Center Bridging (DCB) in the
|
|
driver.
|
|
|
|
If unsure, say N.
|
|
|
|
config IXGBE_IPSEC
|
|
bool "IPSec XFRM cryptography-offload acceleration"
|
|
depends on IXGBE
|
|
depends on XFRM_OFFLOAD
|
|
default y
|
|
select XFRM_ALGO
|
|
---help---
|
|
Enable support for IPSec offload in ixgbe.ko
|
|
|
|
config IXGBEVF
|
|
tristate "Intel(R) 10GbE PCI Express Virtual Function Ethernet support"
|
|
depends on PCI_MSI
|
|
---help---
|
|
This driver supports Intel(R) PCI Express virtual functions for the
|
|
Intel(R) ixgbe driver. For more information on how to identify your
|
|
adapter, go to the Adapter & Driver ID Guide that can be located at:
|
|
|
|
<http://support.intel.com>
|
|
|
|
More specific information on configuring the driver is in
|
|
<file:Documentation/networking/device_drivers/intel/ixgbevf.rst>.
|
|
|
|
To compile this driver as a module, choose M here. The module
|
|
will be called ixgbevf. MSI-X interrupt support is required
|
|
for this driver to work correctly.
|
|
|
|
config IXGBEVF_IPSEC
|
|
bool "IPSec XFRM cryptography-offload acceleration"
|
|
depends on IXGBEVF
|
|
depends on XFRM_OFFLOAD
|
|
default y
|
|
select XFRM_ALGO
|
|
---help---
|
|
Enable support for IPSec offload in ixgbevf.ko
|
|
|
|
config I40E
|
|
tristate "Intel(R) Ethernet Controller XL710 Family support"
|
|
imply PTP_1588_CLOCK
|
|
depends on PCI
|
|
---help---
|
|
This driver supports Intel(R) Ethernet Controller XL710 Family of
|
|
devices. For more information on how to identify your adapter, go
|
|
to the Adapter & Driver ID Guide that can be located at:
|
|
|
|
<http://support.intel.com>
|
|
|
|
More specific information on configuring the driver is in
|
|
<file:Documentation/networking/device_drivers/intel/i40e.rst>.
|
|
|
|
To compile this driver as a module, choose M here. The module
|
|
will be called i40e.
|
|
|
|
config I40E_DCB
|
|
bool "Data Center Bridging (DCB) Support"
|
|
default n
|
|
depends on I40E && DCB
|
|
---help---
|
|
Say Y here if you want to use Data Center Bridging (DCB) in the
|
|
driver.
|
|
|
|
If unsure, say N.
|
|
|
|
# this is here to allow seamless migration from I40EVF --> IAVF name
|
|
# so that CONFIG_IAVF symbol will always mirror the state of CONFIG_I40EVF
|
|
config IAVF
|
|
tristate
|
|
config I40EVF
|
|
tristate "Intel(R) Ethernet Adaptive Virtual Function support"
|
|
select IAVF
|
|
depends on PCI_MSI
|
|
---help---
|
|
This driver supports virtual functions for Intel XL710,
|
|
X710, X722, XXV710, and all devices advertising support for
|
|
Intel Ethernet Adaptive Virtual Function devices. For more
|
|
information on how to identify your adapter, go to the Adapter
|
|
& Driver ID Guide that can be located at:
|
|
|
|
<https://support.intel.com>
|
|
|
|
This driver was formerly named i40evf.
|
|
|
|
More specific information on configuring the driver is in
|
|
<file:Documentation/networking/device_drivers/intel/iavf.rst>.
|
|
|
|
To compile this driver as a module, choose M here. The module
|
|
will be called iavf. MSI-X interrupt support is required
|
|
for this driver to work correctly.
|
|
|
|
config ICE
|
|
tristate "Intel(R) Ethernet Connection E800 Series Support"
|
|
default n
|
|
depends on PCI_MSI
|
|
---help---
|
|
This driver supports Intel(R) Ethernet Connection E800 Series of
|
|
devices. For more information on how to identify your adapter, go
|
|
to the Adapter & Driver ID Guide that can be located at:
|
|
|
|
<http://support.intel.com>
|
|
|
|
More specific information on configuring the driver is in
|
|
<file:Documentation/networking/device_drivers/intel/ice.rst>.
|
|
|
|
To compile this driver as a module, choose M here. The module
|
|
will be called ice.
|
|
|
|
config FM10K
|
|
tristate "Intel(R) FM10000 Ethernet Switch Host Interface Support"
|
|
default n
|
|
depends on PCI_MSI
|
|
imply PTP_1588_CLOCK
|
|
---help---
|
|
This driver supports Intel(R) FM10000 Ethernet Switch Host
|
|
Interface. For more information on how to identify your adapter,
|
|
go to the Adapter & Driver ID Guide that can be located at:
|
|
|
|
<http://support.intel.com>
|
|
|
|
More specific information on configuring the driver is in
|
|
<file:Documentation/networking/device_drivers/intel/fm10k.rst>.
|
|
|
|
To compile this driver as a module, choose M here. The module
|
|
will be called fm10k. MSI-X interrupt support is required
|
|
|
|
config IGC
|
|
tristate "Intel(R) Ethernet Controller I225-LM/I225-V support"
|
|
default n
|
|
depends on PCI
|
|
---help---
|
|
This driver supports Intel(R) Ethernet Controller I225-LM/I225-V
|
|
family of adapters.
|
|
|
|
For more information on how to identify your adapter, go
|
|
to the Adapter & Driver ID Guide that can be located at:
|
|
|
|
<http://support.intel.com>
|
|
|
|
To compile this driver as a module, choose M here. The module
|
|
will be called igc.
|
|
|
|
endif # NET_VENDOR_INTEL
|