mirror of https://gitee.com/openkylin/linux.git
ab6016e0c1
Some Ethernet PHY devices/switches may not properly release the MDIO bus during turn-around time, and fail to drive it low, which can be seen by some controllers as a read failure, while the data clocked in is still correct. Add a boolean property "broken-turn-around" which is parsed by the generic MDIO bus probing code and will set the corresponding bit in the MDIO bus phy_ignore_ta_mask bitmask for MDIO bus drivers to utilize that information. Signed-off-by: Florian Fainelli <f.fainelli@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net> |
||
---|---|---|
.. | ||
unittest-data | ||
Kconfig | ||
Makefile | ||
address.c | ||
base.c | ||
device.c | ||
dynamic.c | ||
fdt.c | ||
fdt_address.c | ||
irq.c | ||
of_mdio.c | ||
of_mtd.c | ||
of_net.c | ||
of_pci.c | ||
of_pci_irq.c | ||
of_private.h | ||
of_reserved_mem.c | ||
overlay.c | ||
pdt.c | ||
platform.c | ||
resolver.c | ||
unittest.c |