linux/Documentation/devicetree/bindings/mtd/fsmc-nand.txt

32 lines
869 B
Plaintext

* FSMC NAND
Required properties:
- compatible : "st,spear600-fsmc-nand", "stericsson,fsmc-nand"
- reg : Address range of the mtd chip
- reg-names: Should contain the reg names "fsmc_regs", "nand_data", "nand_addr" and "nand_cmd"
Optional properties:
- bank-width : Width (in bytes) of the device. If not present, the width
defaults to 1 byte
- nand-skip-bbtscan: Indicates the the BBT scanning should be skipped
Example:
fsmc: flash@d1800000 {
compatible = "st,spear600-fsmc-nand";
#address-cells = <1>;
#size-cells = <1>;
reg = <0xd1800000 0x1000 /* FSMC Register */
0xd2000000 0x0010 /* NAND Base DATA */
0xd2020000 0x0010 /* NAND Base ADDR */
0xd2010000 0x0010>; /* NAND Base CMD */
reg-names = "fsmc_regs", "nand_data", "nand_addr", "nand_cmd";
bank-width = <1>;
nand-skip-bbtscan;
partition@0 {
...
};
};