toshiba_acpi: Fix illumination not available on certain models
Some Toshiba models with illumination support set a different value on the returned codes, thus not allowing the illumination LED to be registered, where it should be. This patch removes a check from toshiba_illumination_available function to allow such models to register the illumination LED. Signed-off-by: Azael Avalos <coproscefalo@gmail.com> Signed-off-by: Darren Hart <dvhart@linux.intel.com>
This commit is contained in:
parent
408a5d136b
commit
12962878fb
|
@ -436,7 +436,7 @@ static int toshiba_illumination_available(struct toshiba_acpi_dev *dev)
|
|||
if (ACPI_FAILURE(status) || out[0] == HCI_FAILURE) {
|
||||
pr_err("ACPI call to query Illumination support failed\n");
|
||||
return 0;
|
||||
} else if (out[0] == HCI_NOT_SUPPORTED || out[1] != 1) {
|
||||
} else if (out[0] == HCI_NOT_SUPPORTED) {
|
||||
pr_info("Illumination device not available\n");
|
||||
return 0;
|
||||
}
|
||||
|
|
Loading…
Reference in New Issue