mirror of https://gitee.com/openkylin/qemu.git
hw/nvme: namespace parameter for EUI-64
The EUI-64 field is the only identifier for NVMe namespaces in UEFI device paths. Add a new namespace property "eui64", that provides the user the option to specify the EUI-64. Signed-off-by: Heinrich Schuchardt <xypron.glpk@gmx.de> Acked-by: Klaus Jensen <k.jensen@samsung.com> Reviewed-by: Klaus Jensen <k.jensen@samsung.com>
This commit is contained in:
parent
3553c48fcb
commit
6870cfb814
|
@ -81,6 +81,10 @@ There are a number of parameters available:
|
|||
Set the UUID of the namespace. This will be reported as a "Namespace UUID"
|
||||
descriptor in the Namespace Identification Descriptor List.
|
||||
|
||||
``eui64``
|
||||
Set the EUI-64 of the namespace. This will be reported as a "IEEE Extended
|
||||
Unique Identifier" descriptor in the Namespace Identification Descriptor List.
|
||||
|
||||
``bus``
|
||||
If there are more ``nvme`` devices defined, this parameter may be used to
|
||||
attach the namespace to a specific ``nvme`` device (identified by an ``id``
|
||||
|
|
|
@ -4426,19 +4426,19 @@ static uint16_t nvme_identify_ns_descr_list(NvmeCtrl *n, NvmeRequest *req)
|
|||
NvmeIdentify *c = (NvmeIdentify *)&req->cmd;
|
||||
uint32_t nsid = le32_to_cpu(c->nsid);
|
||||
uint8_t list[NVME_IDENTIFY_DATA_SIZE] = {};
|
||||
|
||||
struct data {
|
||||
uint8_t *pos = list;
|
||||
struct {
|
||||
NvmeIdNsDescr hdr;
|
||||
uint8_t v[NVME_NIDL_UUID];
|
||||
} uuid;
|
||||
} QEMU_PACKED uuid;
|
||||
struct {
|
||||
NvmeIdNsDescr hdr;
|
||||
uint64_t v;
|
||||
} QEMU_PACKED eui64;
|
||||
struct {
|
||||
NvmeIdNsDescr hdr;
|
||||
uint8_t v;
|
||||
} csi;
|
||||
};
|
||||
|
||||
struct data *ns_descrs = (struct data *)list;
|
||||
} QEMU_PACKED csi;
|
||||
|
||||
trace_pci_nvme_identify_ns_descr_list(nsid);
|
||||
|
||||
|
@ -4452,17 +4452,29 @@ static uint16_t nvme_identify_ns_descr_list(NvmeCtrl *n, NvmeRequest *req)
|
|||
}
|
||||
|
||||
/*
|
||||
* Because the NGUID and EUI64 fields are 0 in the Identify Namespace data
|
||||
* structure, a Namespace UUID (nidt = 3h) must be reported in the
|
||||
* Namespace Identification Descriptor. Add the namespace UUID here.
|
||||
* If the EUI-64 field is 0 and the NGUID field is 0, the namespace must
|
||||
* provide a valid Namespace UUID in the Namespace Identification Descriptor
|
||||
* data structure. QEMU does not yet support setting NGUID.
|
||||
*/
|
||||
ns_descrs->uuid.hdr.nidt = NVME_NIDT_UUID;
|
||||
ns_descrs->uuid.hdr.nidl = NVME_NIDL_UUID;
|
||||
memcpy(&ns_descrs->uuid.v, ns->params.uuid.data, NVME_NIDL_UUID);
|
||||
uuid.hdr.nidt = NVME_NIDT_UUID;
|
||||
uuid.hdr.nidl = NVME_NIDL_UUID;
|
||||
memcpy(uuid.v, ns->params.uuid.data, NVME_NIDL_UUID);
|
||||
memcpy(pos, &uuid, sizeof(uuid));
|
||||
pos += sizeof(uuid);
|
||||
|
||||
ns_descrs->csi.hdr.nidt = NVME_NIDT_CSI;
|
||||
ns_descrs->csi.hdr.nidl = NVME_NIDL_CSI;
|
||||
ns_descrs->csi.v = ns->csi;
|
||||
if (ns->params.eui64) {
|
||||
eui64.hdr.nidt = NVME_NIDT_EUI64;
|
||||
eui64.hdr.nidl = NVME_NIDL_EUI64;
|
||||
eui64.v = cpu_to_be64(ns->params.eui64);
|
||||
memcpy(pos, &eui64, sizeof(eui64));
|
||||
pos += sizeof(eui64);
|
||||
}
|
||||
|
||||
csi.hdr.nidt = NVME_NIDT_CSI;
|
||||
csi.hdr.nidl = NVME_NIDL_CSI;
|
||||
csi.v = ns->csi;
|
||||
memcpy(pos, &csi, sizeof(csi));
|
||||
pos += sizeof(csi);
|
||||
|
||||
return nvme_c2h(n, list, sizeof(list), req);
|
||||
}
|
||||
|
|
|
@ -77,6 +77,7 @@ static int nvme_ns_init(NvmeNamespace *ns, Error **errp)
|
|||
id_ns->mssrl = cpu_to_le16(ns->params.mssrl);
|
||||
id_ns->mcl = cpu_to_le32(ns->params.mcl);
|
||||
id_ns->msrc = ns->params.msrc;
|
||||
id_ns->eui64 = cpu_to_be64(ns->params.eui64);
|
||||
|
||||
ds = 31 - clz32(ns->blkconf.logical_block_size);
|
||||
ms = ns->params.ms;
|
||||
|
@ -511,6 +512,7 @@ static Property nvme_ns_props[] = {
|
|||
DEFINE_PROP_BOOL("shared", NvmeNamespace, params.shared, false),
|
||||
DEFINE_PROP_UINT32("nsid", NvmeNamespace, params.nsid, 0),
|
||||
DEFINE_PROP_UUID("uuid", NvmeNamespace, params.uuid),
|
||||
DEFINE_PROP_UINT64("eui64", NvmeNamespace, params.eui64, 0),
|
||||
DEFINE_PROP_UINT16("ms", NvmeNamespace, params.ms, 0),
|
||||
DEFINE_PROP_UINT8("mset", NvmeNamespace, params.mset, 0),
|
||||
DEFINE_PROP_UINT8("pi", NvmeNamespace, params.pi, 0),
|
||||
|
|
|
@ -83,6 +83,7 @@ typedef struct NvmeNamespaceParams {
|
|||
bool shared;
|
||||
uint32_t nsid;
|
||||
QemuUUID uuid;
|
||||
uint64_t eui64;
|
||||
|
||||
uint16_t ms;
|
||||
uint8_t mset;
|
||||
|
|
Loading…
Reference in New Issue