hw/intc/arm_gicv3_its: Don't use data if reading command failed

In process_cmdq(), we read 64 bits of the command packet, which
contain the command identifier, which we then switch() on to dispatch
to an appropriate sub-function.  However, if address_space_ldq_le()
reports a memory transaction failure, we still read the command
identifier out of the data and switch() on it.  Restructure the code
so that we stop immediately (stalling the command queue) in this
case.

Signed-off-by: Peter Maydell <peter.maydell@linaro.org>
Reviewed-by: Alex Bennée <alex.bennee@linaro.org>
Reviewed-by: Richard Henderson <richard.henderson@linaro.org>
Message-id: 20220111171048.3545974-5-peter.maydell@linaro.org
This commit is contained in:
Peter Maydell 2022-01-11 17:10:39 +00:00
parent 7d62b2dcdb
commit f0b4b2a28c
1 changed files with 6 additions and 1 deletions

View File

@ -672,8 +672,13 @@ static void process_cmdq(GICv3ITSState *s)
data = address_space_ldq_le(as, s->cq.base_addr + cq_offset,
MEMTXATTRS_UNSPECIFIED, &res);
if (res != MEMTX_OK) {
result = false;
s->creadr = FIELD_DP64(s->creadr, GITS_CREADR, STALLED, 1);
qemu_log_mask(LOG_GUEST_ERROR,
"%s: could not read command at 0x%" PRIx64 "\n",
__func__, s->cq.base_addr + cq_offset);
break;
}
cmd = (data & CMD_MASK);
switch (cmd) {