mirror of https://gitee.com/openkylin/wget.git
304 lines
8.0 KiB
C
304 lines
8.0 KiB
C
/* Emergency actions in case of a fatal signal.
|
|
Copyright (C) 2003-2004, 2006-2019 Free Software Foundation, Inc.
|
|
Written by Bruno Haible <bruno@clisp.org>, 2003.
|
|
|
|
This program is free software: you can redistribute it and/or modify
|
|
it under the terms of the GNU General Public License as published by
|
|
the Free Software Foundation; either version 3 of the License, or
|
|
(at your option) any later version.
|
|
|
|
This program is distributed in the hope that it will be useful,
|
|
but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
GNU General Public License for more details.
|
|
|
|
You should have received a copy of the GNU General Public License
|
|
along with this program. If not, see <https://www.gnu.org/licenses/>. */
|
|
|
|
|
|
#include <config.h>
|
|
|
|
/* Specification. */
|
|
#include "fatal-signal.h"
|
|
|
|
#include <stdbool.h>
|
|
#include <stdlib.h>
|
|
#include <signal.h>
|
|
#include <unistd.h>
|
|
|
|
#include "sig-handler.h"
|
|
#include "xalloc.h"
|
|
|
|
#define SIZEOF(a) (sizeof(a) / sizeof(a[0]))
|
|
|
|
/* ========================================================================= */
|
|
|
|
|
|
/* The list of fatal signals.
|
|
These are those signals whose default action is to terminate the process
|
|
without a core dump, except
|
|
SIGKILL - because it cannot be caught,
|
|
SIGALRM SIGUSR1 SIGUSR2 SIGPOLL SIGIO SIGLOST - because applications
|
|
often use them for their own purpose,
|
|
SIGPROF SIGVTALRM - because they are used for profiling,
|
|
SIGSTKFLT - because it is more similar to SIGFPE, SIGSEGV, SIGBUS,
|
|
SIGSYS - because it is more similar to SIGABRT, SIGSEGV,
|
|
SIGPWR - because it of too special use,
|
|
SIGRTMIN...SIGRTMAX - because they are reserved for application use.
|
|
plus
|
|
SIGXCPU, SIGXFSZ - because they are quite similar to SIGTERM. */
|
|
|
|
static int fatal_signals[] =
|
|
{
|
|
/* ISO C 99 signals. */
|
|
#ifdef SIGINT
|
|
SIGINT,
|
|
#endif
|
|
#ifdef SIGTERM
|
|
SIGTERM,
|
|
#endif
|
|
/* POSIX:2001 signals. */
|
|
#ifdef SIGHUP
|
|
SIGHUP,
|
|
#endif
|
|
#ifdef SIGPIPE
|
|
SIGPIPE,
|
|
#endif
|
|
/* BSD signals. */
|
|
#ifdef SIGXCPU
|
|
SIGXCPU,
|
|
#endif
|
|
#ifdef SIGXFSZ
|
|
SIGXFSZ,
|
|
#endif
|
|
/* Native Windows signals. */
|
|
#ifdef SIGBREAK
|
|
SIGBREAK,
|
|
#endif
|
|
0
|
|
};
|
|
|
|
#define num_fatal_signals (SIZEOF (fatal_signals) - 1)
|
|
|
|
/* Eliminate signals whose signal handler is SIG_IGN. */
|
|
|
|
static void
|
|
init_fatal_signals (void)
|
|
{
|
|
static bool fatal_signals_initialized = false;
|
|
if (!fatal_signals_initialized)
|
|
{
|
|
size_t i;
|
|
|
|
for (i = 0; i < num_fatal_signals; i++)
|
|
{
|
|
struct sigaction action;
|
|
|
|
if (sigaction (fatal_signals[i], NULL, &action) >= 0
|
|
&& get_handler (&action) == SIG_IGN)
|
|
fatal_signals[i] = -1;
|
|
}
|
|
|
|
fatal_signals_initialized = true;
|
|
}
|
|
}
|
|
|
|
|
|
/* ========================================================================= */
|
|
|
|
|
|
typedef _GL_ASYNC_SAFE void (*action_t) (int sig);
|
|
|
|
/* Type of an entry in the actions array.
|
|
The 'action' field is accessed from within the fatal_signal_handler(),
|
|
therefore we mark it as 'volatile'. */
|
|
typedef struct
|
|
{
|
|
volatile action_t action;
|
|
}
|
|
actions_entry_t;
|
|
|
|
/* The registered cleanup actions. */
|
|
static actions_entry_t static_actions[32];
|
|
static actions_entry_t * volatile actions = static_actions;
|
|
static sig_atomic_t volatile actions_count = 0;
|
|
static size_t actions_allocated = SIZEOF (static_actions);
|
|
|
|
|
|
/* The saved signal handlers.
|
|
Size 32 would not be sufficient: On HP-UX, SIGXCPU = 33, SIGXFSZ = 34. */
|
|
static struct sigaction saved_sigactions[64];
|
|
|
|
|
|
/* Uninstall the handlers. */
|
|
static _GL_ASYNC_SAFE void
|
|
uninstall_handlers (void)
|
|
{
|
|
size_t i;
|
|
|
|
for (i = 0; i < num_fatal_signals; i++)
|
|
if (fatal_signals[i] >= 0)
|
|
{
|
|
int sig = fatal_signals[i];
|
|
if (saved_sigactions[sig].sa_handler == SIG_IGN)
|
|
saved_sigactions[sig].sa_handler = SIG_DFL;
|
|
sigaction (sig, &saved_sigactions[sig], NULL);
|
|
}
|
|
}
|
|
|
|
|
|
/* The signal handler. It gets called asynchronously. */
|
|
static _GL_ASYNC_SAFE void
|
|
fatal_signal_handler (int sig)
|
|
{
|
|
for (;;)
|
|
{
|
|
/* Get the last registered cleanup action, in a reentrant way. */
|
|
action_t action;
|
|
size_t n = actions_count;
|
|
if (n == 0)
|
|
break;
|
|
n--;
|
|
actions_count = n;
|
|
action = actions[n].action;
|
|
/* Execute the action. */
|
|
action (sig);
|
|
}
|
|
|
|
/* Now execute the signal's default action.
|
|
If the signal being delivered was blocked, the re-raised signal would be
|
|
delivered when this handler returns. But the way we install this handler,
|
|
no signal is blocked, and the re-raised signal is delivered already
|
|
during raise(). */
|
|
uninstall_handlers ();
|
|
raise (sig);
|
|
}
|
|
|
|
|
|
/* Install the handlers. */
|
|
static void
|
|
install_handlers (void)
|
|
{
|
|
size_t i;
|
|
struct sigaction action;
|
|
|
|
action.sa_handler = &fatal_signal_handler;
|
|
/* If we get a fatal signal while executing fatal_signal_handler, enter
|
|
fatal_signal_handler recursively, since it is reentrant. Hence no
|
|
SA_RESETHAND. */
|
|
action.sa_flags = SA_NODEFER;
|
|
sigemptyset (&action.sa_mask);
|
|
for (i = 0; i < num_fatal_signals; i++)
|
|
if (fatal_signals[i] >= 0)
|
|
{
|
|
int sig = fatal_signals[i];
|
|
|
|
if (!(sig < sizeof (saved_sigactions) / sizeof (saved_sigactions[0])))
|
|
abort ();
|
|
sigaction (sig, &action, &saved_sigactions[sig]);
|
|
}
|
|
}
|
|
|
|
|
|
/* Register a cleanup function to be executed when a catchable fatal signal
|
|
occurs. */
|
|
void
|
|
at_fatal_signal (action_t action)
|
|
{
|
|
static bool cleanup_initialized = false;
|
|
if (!cleanup_initialized)
|
|
{
|
|
init_fatal_signals ();
|
|
install_handlers ();
|
|
cleanup_initialized = true;
|
|
}
|
|
|
|
if (actions_count == actions_allocated)
|
|
{
|
|
/* Extend the actions array. Note that we cannot use xrealloc(),
|
|
because then the cleanup() function could access an already
|
|
deallocated array. */
|
|
actions_entry_t *old_actions = actions;
|
|
size_t old_actions_allocated = actions_allocated;
|
|
size_t new_actions_allocated = 2 * actions_allocated;
|
|
actions_entry_t *new_actions =
|
|
XNMALLOC (new_actions_allocated, actions_entry_t);
|
|
size_t k;
|
|
|
|
/* Don't use memcpy() here, because memcpy takes non-volatile arguments
|
|
and is therefore not guaranteed to complete all memory stores before
|
|
the next statement. */
|
|
for (k = 0; k < old_actions_allocated; k++)
|
|
new_actions[k] = old_actions[k];
|
|
actions = new_actions;
|
|
actions_allocated = new_actions_allocated;
|
|
/* Now we can free the old actions array. */
|
|
if (old_actions != static_actions)
|
|
free (old_actions);
|
|
}
|
|
/* The two uses of 'volatile' in the types above (and ISO C 99 section
|
|
5.1.2.3.(5)) ensure that we increment the actions_count only after
|
|
the new action has been written to the memory location
|
|
actions[actions_count]. */
|
|
actions[actions_count].action = action;
|
|
actions_count++;
|
|
}
|
|
|
|
|
|
/* ========================================================================= */
|
|
|
|
|
|
static sigset_t fatal_signal_set;
|
|
|
|
static void
|
|
init_fatal_signal_set (void)
|
|
{
|
|
static bool fatal_signal_set_initialized = false;
|
|
if (!fatal_signal_set_initialized)
|
|
{
|
|
size_t i;
|
|
|
|
init_fatal_signals ();
|
|
|
|
sigemptyset (&fatal_signal_set);
|
|
for (i = 0; i < num_fatal_signals; i++)
|
|
if (fatal_signals[i] >= 0)
|
|
sigaddset (&fatal_signal_set, fatal_signals[i]);
|
|
|
|
fatal_signal_set_initialized = true;
|
|
}
|
|
}
|
|
|
|
/* Temporarily delay the catchable fatal signals. */
|
|
void
|
|
block_fatal_signals (void)
|
|
{
|
|
init_fatal_signal_set ();
|
|
sigprocmask (SIG_BLOCK, &fatal_signal_set, NULL);
|
|
}
|
|
|
|
/* Stop delaying the catchable fatal signals. */
|
|
void
|
|
unblock_fatal_signals (void)
|
|
{
|
|
init_fatal_signal_set ();
|
|
sigprocmask (SIG_UNBLOCK, &fatal_signal_set, NULL);
|
|
}
|
|
|
|
|
|
unsigned int
|
|
get_fatal_signals (int signals[64])
|
|
{
|
|
init_fatal_signal_set ();
|
|
|
|
{
|
|
int *p = signals;
|
|
size_t i;
|
|
|
|
for (i = 0; i < num_fatal_signals; i++)
|
|
if (fatal_signals[i] >= 0)
|
|
*p++ = fatal_signals[i];
|
|
return p - signals;
|
|
}
|
|
}
|