ARM: orion5x: move interrupt controller node into ocp
The interrupt controller node was located outside of the ocp@f1000000 node, which doesn't make much sense: like any other device, the interrupt controller has registers located in the "Internal Registers Window", so it is much more logical to have it under the ocp@f1000000 node. It is even more important as we are going to move Orion5x to use the Device Tree binding of the mvebu-mbus driver. Signed-off-by: Thomas Petazzoni <thomas.petazzoni@free-electrons.com> Link: https://lkml.kernel.org/r/1398202002-28530-11-git-send-email-thomas.petazzoni@free-electrons.com Acked-by: Sebastian Hesselbarth <sebastian.hesselbarth@gmail.com> Signed-off-by: Jason Cooper <jason@lakedaemon.net>
This commit is contained in:
parent
c9eaa447e7
commit
0fb28811dd
|
@ -17,13 +17,6 @@ aliases {
|
|||
gpio0 = &gpio0;
|
||||
};
|
||||
|
||||
intc: interrupt-controller {
|
||||
compatible = "marvell,orion-intc";
|
||||
interrupt-controller;
|
||||
#interrupt-cells = <1>;
|
||||
reg = <0xf1020200 0x08>;
|
||||
};
|
||||
|
||||
ocp@f1000000 {
|
||||
compatible = "simple-bus";
|
||||
ranges = <0x00000000 0xf1000000 0x4000000
|
||||
|
@ -79,6 +72,13 @@ serial@12100 {
|
|||
status = "disabled";
|
||||
};
|
||||
|
||||
intc: interrupt-controller@20200 {
|
||||
compatible = "marvell,orion-intc";
|
||||
interrupt-controller;
|
||||
#interrupt-cells = <1>;
|
||||
reg = <0x20200 0x08>;
|
||||
};
|
||||
|
||||
wdt@20300 {
|
||||
compatible = "marvell,orion-wdt";
|
||||
reg = <0x20300 0x28>;
|
||||
|
|