habanalabs: fix pm manual->auto in GOYA
When moving from manual to automatic power management mode in GOYA, the driver didn't correctly place the device in LOW power mode. As a result, if an application was run immediately after the move, it would have run with low frequencies. Reviewed-by: Omer Shpigelman <oshpigelman@habana.ai> Signed-off-by: Oded Gabbay <oded.gabbay@gmail.com>
This commit is contained in:
parent
6966d9e1f2
commit
1184550155
|
@ -298,8 +298,8 @@ static ssize_t pm_mng_profile_store(struct device *dev,
|
|||
/* Make sure we are in LOW PLL when changing modes */
|
||||
if (hdev->pm_mng_profile == PM_MANUAL) {
|
||||
hdev->curr_pll_profile = PLL_HIGH;
|
||||
hl_device_set_frequency(hdev, PLL_LOW);
|
||||
hdev->pm_mng_profile = PM_AUTO;
|
||||
hl_device_set_frequency(hdev, PLL_LOW);
|
||||
}
|
||||
} else if (strncmp("manual", buf, strlen("manual")) == 0) {
|
||||
if (hdev->pm_mng_profile == PM_AUTO) {
|
||||
|
|