USB: OHCI: fix bad #define in ohci-tmio.c
An incorrect definition of CCR_PM_USBPW3 in ohci-tmio.c is a perennial source of invalid diagnoses from static scanners, such as in <http://marc.info/?l=linux-usb&m=143634574527641&w=2>. This patch fixes the definition. Signed-off-by: Alan Stern <stern@rowland.harvard.edu> Reported-by: David Binderman <dcb314@hotmail.com> CC: Dmitry Eremin-Solenikov <dbaryshkov@gmail.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
parent
91b725600d
commit
1209544d8a
|
@ -58,7 +58,7 @@
|
|||
#define CCR_PM_CKRNEN 0x0002
|
||||
#define CCR_PM_USBPW1 0x0004
|
||||
#define CCR_PM_USBPW2 0x0008
|
||||
#define CCR_PM_USBPW3 0x0008
|
||||
#define CCR_PM_USBPW3 0x0010
|
||||
#define CCR_PM_PMEE 0x0100
|
||||
#define CCR_PM_PMES 0x8000
|
||||
|
||||
|
|