RDMA/hns: Bugfix for CM test

It will print the warning when the MSB bit of SLID is not zero running
cm_req_handler function that test CM. It needs to fixed zero when test
RoCE device.

Signed-off-by: Lijun Ou <oulijun@huawei.com>
Signed-off-by: Jason Gunthorpe <jgg@mellanox.com>
This commit is contained in:
Lijun Ou 2018-09-30 17:00:30 +08:00 committed by Jason Gunthorpe
parent c80e066100
commit 15fc056fba
1 changed files with 1 additions and 0 deletions

View File

@ -2321,6 +2321,7 @@ static int hns_roce_v2_poll_one(struct hns_roce_cq *hr_cq,
wc->src_qp = (u8)roce_get_field(cqe->byte_32,
V2_CQE_BYTE_32_RMT_QPN_M,
V2_CQE_BYTE_32_RMT_QPN_S);
wc->slid = 0;
wc->wc_flags |= (roce_get_bit(cqe->byte_32,
V2_CQE_BYTE_32_GRH_S) ?
IB_WC_GRH : 0);