rtc: m41t80: fix SQWE override when setting an alarm
Currently setting an alarm clears the SQWE bit which means that the clock output is disabled no matter its previous state. Signed-off-by: Gary Bisson <gary.bisson@boundarydevices.com> Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
This commit is contained in:
parent
8066360744
commit
2de9261c18
|
@ -332,6 +332,9 @@ static int m41t80_set_alarm(struct device *dev, struct rtc_wkalrm *alrm)
|
||||||
return err;
|
return err;
|
||||||
}
|
}
|
||||||
|
|
||||||
|
/* Keep SQWE bit value */
|
||||||
|
alarmvals[0] |= (ret & M41T80_ALMON_SQWE);
|
||||||
|
|
||||||
ret = i2c_smbus_read_byte_data(client, M41T80_REG_FLAGS);
|
ret = i2c_smbus_read_byte_data(client, M41T80_REG_FLAGS);
|
||||||
if (ret < 0)
|
if (ret < 0)
|
||||||
return ret;
|