ARM: EXYNOS: Fix UART address selection for DEBUG_LL
The Exynos542x SoCs using A15+A7 can boot to A15 or A7. If it boots using A7 (like on Odroid XU family boards), it can't choose right UART physical address only the part number of CP15. Fix the detection logic by checking the Cluster ID additionally. Signed-off-by: Joonyoung Shim <jy0922.shim@samsung.com> Tested-by: Marek Szyprowski <m.szyprowski@samsung.com> [k.kozlowski: Extend commit message] Signed-off-by: Krzysztof Kozlowski <k.kozlowski@samsung.com>
This commit is contained in:
parent
17e0645e6b
commit
2f3428b5cf
|
@ -24,7 +24,11 @@
|
|||
mrc p15, 0, \tmp, c0, c0, 0
|
||||
and \tmp, \tmp, #0xf0
|
||||
teq \tmp, #0xf0 @@ A15
|
||||
ldreq \rp, =EXYNOS5_PA_UART
|
||||
beq 100f
|
||||
mrc p15, 0, \tmp, c0, c0, 5
|
||||
and \tmp, \tmp, #0xf00
|
||||
teq \tmp, #0x100 @@ A15 + A7 but boot to A7
|
||||
100: ldreq \rp, =EXYNOS5_PA_UART
|
||||
movne \rp, #EXYNOS4_PA_UART @@ EXYNOS4
|
||||
ldr \rv, =S3C_VA_UART
|
||||
#if CONFIG_DEBUG_S3C_UART != 0
|
||||
|
|