iio: fix pressure data output unit in hid-sensor-attributes

According to IIO ABI definition, IIO_PRESSURE data output unit is
kilopascal:
http://lxr.free-electrons.com/source/Documentation/ABI/testing/sysfs-bus-iio

This patch fix output unit of HID pressure sensor IIO driver from pascal to
kilopascal to follow IIO ABI definition.

Signed-off-by: Kweh, Hock Leong <hock.leong.kweh@intel.com>
Reviewed-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
This commit is contained in:
Kweh, Hock Leong 2016-08-29 18:50:56 +08:00 committed by Jonathan Cameron
parent f8e81d7e49
commit 36afb176d3
1 changed files with 2 additions and 2 deletions

View File

@ -56,8 +56,8 @@ static struct {
{HID_USAGE_SENSOR_ALS, 0, 1, 0},
{HID_USAGE_SENSOR_ALS, HID_USAGE_SENSOR_UNITS_LUX, 1, 0},
{HID_USAGE_SENSOR_PRESSURE, 0, 100000, 0},
{HID_USAGE_SENSOR_PRESSURE, HID_USAGE_SENSOR_UNITS_PASCAL, 1, 0},
{HID_USAGE_SENSOR_PRESSURE, 0, 100, 0},
{HID_USAGE_SENSOR_PRESSURE, HID_USAGE_SENSOR_UNITS_PASCAL, 0, 1000},
};
static int pow_10(unsigned power)