thermal: cpu_cooling: Use cpufreq_dev->freq_table for finding level/freq
get_property() was an over complicated beast with BUGs. It used to believe that cpufreq table is present in ascending or descending order, which might not always be true. Previous patch has created another freq table in descending order for us and we better use it now. With that get_property() simply goes away and another helper get_level() comes in. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
This commit is contained in:
parent
f6859014c7
commit
4843c4a190
|
@ -112,85 +112,27 @@ static void release_idr(struct idr *idr, int id)
|
|||
|
||||
/* Below code defines functions to be used for cpufreq as cooling device */
|
||||
|
||||
enum cpufreq_cooling_property {
|
||||
GET_LEVEL,
|
||||
GET_FREQ,
|
||||
};
|
||||
|
||||
/**
|
||||
* get_property - fetch a property of interest for a given cpu.
|
||||
* get_level: Find the level for a particular frequency
|
||||
* @cpufreq_dev: cpufreq_dev for which the property is required
|
||||
* @input: query parameter
|
||||
* @output: query return
|
||||
* @property: type of query (frequency, level)
|
||||
* @freq: Frequency
|
||||
*
|
||||
* This is the common function to
|
||||
* 1. translate frequency to cooling state
|
||||
* 2. translate cooling state to frequency
|
||||
*
|
||||
* Note that the code may be not in good shape
|
||||
* but it is written in this way in order to:
|
||||
* a) reduce duplicate code as most of the code can be shared.
|
||||
* b) make sure the logic is consistent when translating between
|
||||
* cooling states and frequencies.
|
||||
*
|
||||
* Return: 0 on success, -EINVAL when invalid parameters are passed.
|
||||
* Return: level on success, THERMAL_CSTATE_INVALID on error.
|
||||
*/
|
||||
static int get_property(struct cpufreq_cooling_device *cpufreq_dev,
|
||||
unsigned long input, unsigned int *output,
|
||||
enum cpufreq_cooling_property property)
|
||||
static unsigned long get_level(struct cpufreq_cooling_device *cpufreq_dev,
|
||||
unsigned int freq)
|
||||
{
|
||||
int i;
|
||||
unsigned long level = 0;
|
||||
unsigned int freq = CPUFREQ_ENTRY_INVALID;
|
||||
int descend = -1;
|
||||
struct cpufreq_frequency_table *pos, *table;
|
||||
unsigned long level;
|
||||
|
||||
if (!output)
|
||||
return -EINVAL;
|
||||
for (level = 0; level <= cpufreq_dev->max_level; level++) {
|
||||
if (freq == cpufreq_dev->freq_table[level])
|
||||
return level;
|
||||
|
||||
table = cpufreq_frequency_get_table(cpumask_first(&cpufreq_dev->allowed_cpus));
|
||||
if (!table)
|
||||
return -EINVAL;
|
||||
|
||||
cpufreq_for_each_valid_entry(pos, table) {
|
||||
/* ignore duplicate entry */
|
||||
if (freq == pos->frequency)
|
||||
continue;
|
||||
|
||||
/* get the frequency order */
|
||||
if (freq != CPUFREQ_ENTRY_INVALID && descend == -1)
|
||||
descend = freq > pos->frequency;
|
||||
|
||||
freq = pos->frequency;
|
||||
if (freq > cpufreq_dev->freq_table[level])
|
||||
break;
|
||||
}
|
||||
|
||||
if (property == GET_FREQ)
|
||||
level = descend ? input : (cpufreq_dev->max_level - input);
|
||||
|
||||
i = 0;
|
||||
cpufreq_for_each_valid_entry(pos, table) {
|
||||
/* ignore duplicate entry */
|
||||
if (freq == pos->frequency)
|
||||
continue;
|
||||
|
||||
/* now we have a valid frequency entry */
|
||||
freq = pos->frequency;
|
||||
|
||||
if (property == GET_LEVEL && (unsigned int)input == freq) {
|
||||
/* get level by frequency */
|
||||
*output = descend ? i : (cpufreq_dev->max_level - i);
|
||||
return 0;
|
||||
}
|
||||
if (property == GET_FREQ && level == i) {
|
||||
/* get frequency by level */
|
||||
*output = freq;
|
||||
return 0;
|
||||
}
|
||||
i++;
|
||||
}
|
||||
|
||||
return -EINVAL;
|
||||
return THERMAL_CSTATE_INVALID;
|
||||
}
|
||||
|
||||
/**
|
||||
|
@ -211,14 +153,8 @@ unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq)
|
|||
mutex_lock(&cooling_cpufreq_lock);
|
||||
list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) {
|
||||
if (cpumask_test_cpu(cpu, &cpufreq_dev->allowed_cpus)) {
|
||||
unsigned int val;
|
||||
|
||||
mutex_unlock(&cooling_cpufreq_lock);
|
||||
if (get_property(cpufreq_dev, (unsigned long)freq, &val,
|
||||
GET_LEVEL))
|
||||
return THERMAL_CSTATE_INVALID;
|
||||
|
||||
return (unsigned long)val;
|
||||
return get_level(cpufreq_dev, freq);
|
||||
}
|
||||
}
|
||||
mutex_unlock(&cooling_cpufreq_lock);
|
||||
|
@ -323,16 +259,16 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,
|
|||
struct cpufreq_cooling_device *cpufreq_device = cdev->devdata;
|
||||
unsigned int cpu = cpumask_any(&cpufreq_device->allowed_cpus);
|
||||
unsigned int clip_freq;
|
||||
int ret;
|
||||
|
||||
/* Request state should be less than max_level */
|
||||
if (WARN_ON(state > cpufreq_device->max_level))
|
||||
return -EINVAL;
|
||||
|
||||
/* Check if the old cooling action is same as new cooling action */
|
||||
if (cpufreq_device->cpufreq_state == state)
|
||||
return 0;
|
||||
|
||||
ret = get_property(cpufreq_device, state, &clip_freq, GET_FREQ);
|
||||
if (ret)
|
||||
return ret;
|
||||
|
||||
clip_freq = cpufreq_device->freq_table[state];
|
||||
cpufreq_device->cpufreq_state = state;
|
||||
cpufreq_device->cpufreq_val = clip_freq;
|
||||
|
||||
|
@ -402,13 +338,6 @@ __cpufreq_cooling_register(struct device_node *np,
|
|||
if (!cpufreq_dev)
|
||||
return ERR_PTR(-ENOMEM);
|
||||
|
||||
ret = get_property(cpufreq_dev, 0, &cpufreq_dev->cpufreq_val, GET_FREQ);
|
||||
if (ret) {
|
||||
pr_err("%s: Failed to get frequency: %d", __func__, ret);
|
||||
cool_dev = ERR_PTR(ret);
|
||||
goto free_cdev;
|
||||
}
|
||||
|
||||
/* Find max levels */
|
||||
cpufreq_for_each_valid_entry(pos, table)
|
||||
cpufreq_dev->max_level++;
|
||||
|
@ -452,6 +381,7 @@ __cpufreq_cooling_register(struct device_node *np,
|
|||
pr_debug("%s: freq:%u KHz\n", __func__, freq);
|
||||
}
|
||||
|
||||
cpufreq_dev->cpufreq_val = cpufreq_dev->freq_table[0];
|
||||
cpufreq_dev->cool_dev = cool_dev;
|
||||
|
||||
mutex_lock(&cooling_cpufreq_lock);
|
||||
|
|
Loading…
Reference in New Issue