ARM: dts: am43xx-clocks: use ti, fixed-factor-clock for dpll_per_clkdcoldo
Use the ti,fixed-factor-clock version so that autoidle for dpll_per_clkdcoldo is properly controlled after power management code is introduced. Without this the clock may be held active even when it is gated. Signed-off-by: Dave Gerlach <d-gerlach@ti.com> Signed-off-by: Tero Kristo <t-kristo@ti.com>
This commit is contained in:
parent
89ca3b8819
commit
50b9689408
|
@ -609,10 +609,13 @@ dpll_ddr_m4_ck: dpll_ddr_m4_ck {
|
|||
|
||||
dpll_per_clkdcoldo: dpll_per_clkdcoldo {
|
||||
#clock-cells = <0>;
|
||||
compatible = "fixed-factor-clock";
|
||||
compatible = "ti,fixed-factor-clock";
|
||||
clocks = <&dpll_per_ck>;
|
||||
clock-mult = <1>;
|
||||
clock-div = <1>;
|
||||
ti,clock-mult = <1>;
|
||||
ti,clock-div = <1>;
|
||||
ti,autoidle-shift = <8>;
|
||||
reg = <0x2e14>;
|
||||
ti,invert-autoidle-bit;
|
||||
};
|
||||
|
||||
dll_aging_clk_div: dll_aging_clk_div {
|
||||
|
|