drm/amd/powerplay: fix fan speed percent setting error on Polaris10
The logic was reversed. Signed-off-by: Eric Huang <JinHuiEric.Huang@amd.com> Reviewed-by: Alex Deucher <alexander.deucher@amd.com> Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
This commit is contained in:
parent
681ed01c62
commit
5122438954
|
@ -220,8 +220,8 @@ int polaris10_fan_ctrl_set_fan_speed_percent(struct pp_hwmgr *hwmgr,
|
|||
if (duty100 == 0)
|
||||
return -EINVAL;
|
||||
|
||||
tmp64 = (uint64_t)speed * 100;
|
||||
do_div(tmp64, duty100);
|
||||
tmp64 = (uint64_t)speed * duty100;
|
||||
do_div(tmp64, 100);
|
||||
duty = (uint32_t)tmp64;
|
||||
|
||||
PHM_WRITE_VFPF_INDIRECT_FIELD(hwmgr->device, CGS_IND_REG__SMC,
|
||||
|
|
Loading…