clk: sunxi-ng: h6: fix PWM gate/reset offset
Currently the register offset of the PWM bus gate in Allwinner H6 clock driver is wrong. Fix this issue. Fixes: 542353ea ("clk: sunxi-ng: add support for the Allwinner H6 CCU") Signed-off-by: Rongyi Chen <chenyi@tt-cool.com> [Icenowy: refactor commit message] Signed-off-by: Icenowy Zheng <icenowy@aosc.io> Signed-off-by: Chen-Yu Tsai <wens@csie.org>
This commit is contained in:
parent
2852bfbf4f
commit
58c0f79887
|
@ -352,7 +352,7 @@ static SUNXI_CCU_GATE(bus_dbg_clk, "bus-dbg", "psi-ahb1-ahb2",
|
|||
static SUNXI_CCU_GATE(bus_psi_clk, "bus-psi", "psi-ahb1-ahb2",
|
||||
0x79c, BIT(0), 0);
|
||||
|
||||
static SUNXI_CCU_GATE(bus_pwm_clk, "bus-pwm", "apb1", 0x79c, BIT(0), 0);
|
||||
static SUNXI_CCU_GATE(bus_pwm_clk, "bus-pwm", "apb1", 0x7ac, BIT(0), 0);
|
||||
|
||||
static SUNXI_CCU_GATE(bus_iommu_clk, "bus-iommu", "apb1", 0x7bc, BIT(0), 0);
|
||||
|
||||
|
|
Loading…