libata-scsi: reject WRITE SAME (16) with n_block that exceeds limit
Currently if a WRITE SAME (16) command is issued to the SATL with "number of blocks" that is larger than the "Maximum write same length" (which is the maximum number of blocks per TRIM command allowed in libata, currently 65535 * 512 / 8 blocks), the SATL will accept the command and translate it to a TRIM command with the upper limit. However, according to SBC (as of sbc4r11.pdf), the "device server" should terminate the command with "Invalid field in CDB" in that case. Signed-off-by: Tom Yan <tom.ty89@gmail.com> Signed-off-by: Tejun Heo <tj@kernel.org>
This commit is contained in:
parent
f086b7489a
commit
5c79097a28
|
@ -3310,7 +3310,13 @@ static unsigned int ata_scsi_write_same_xlat(struct ata_queued_cmd *qc)
|
|||
goto invalid_param_len;
|
||||
|
||||
buf = page_address(sg_page(scsi_sglist(scmd)));
|
||||
size = ata_set_lba_range_entries(buf, 512, block, n_block);
|
||||
|
||||
if (n_block <= 65535 * 512 / 8) {
|
||||
size = ata_set_lba_range_entries(buf, 512, block, n_block);
|
||||
} else {
|
||||
fp = 2;
|
||||
goto invalid_fld;
|
||||
}
|
||||
|
||||
if (ata_ncq_enabled(dev) && ata_fpdma_dsm_supported(dev)) {
|
||||
/* Newer devices support queued TRIM commands */
|
||||
|
|
Loading…