drm: Add data transmission order bus flag
The flags indicate whether data is transmitted LSB to MSB or MSB to LSB on the bus. The exact meaning is bus-type dependent. For instance, for LVDS buses the flags indicate whether the seven data bits transmitted in a clock pulse are sent in normal order (MSB to LSB, slots 0 to 6) or reverse order (LSB to MSB, slots 6 to 0). Signed-off-by: Laurent Pinchart <laurent.pinchart+renesas@ideasonboard.com> Reviewed-by: Thierry Reding <treding@nvidia.com>
This commit is contained in:
parent
0b5a3042b7
commit
5ec1a96010
|
@ -224,6 +224,10 @@ struct drm_display_info {
|
|||
#define DRM_BUS_FLAG_PIXDATA_POSEDGE (1<<2)
|
||||
/* drive data on neg. edge */
|
||||
#define DRM_BUS_FLAG_PIXDATA_NEGEDGE (1<<3)
|
||||
/* data is transmitted MSB to LSB on the bus */
|
||||
#define DRM_BUS_FLAG_DATA_MSB_TO_LSB (1<<4)
|
||||
/* data is transmitted LSB to MSB on the bus */
|
||||
#define DRM_BUS_FLAG_DATA_LSB_TO_MSB (1<<5)
|
||||
|
||||
/**
|
||||
* @bus_flags: Additional information (like pixel signal polarity) for
|
||||
|
|