net/mlx4_en: Fix type mismatch for 32-bit systems
is_power_of_2 expects unsigned long and we pass u64 max_val_cycles,
this will be truncated on 32 bit systems, and the result is not what we
were expecting.
div_u64 expects u32 as a second argument and we pass
max_val_cycles_rounded which is u64 hence it will always be truncated.
Fix was tested on both 64 and 32 bit systems and got same results for
max_val_cycles and max_val_cycles_rounded.
Fixes: 4850cf4581
("net/mlx4_en: Resolve dividing by zero in 32-bit system")
Signed-off-by: Slava Shwartsman <slavash@mellanox.com>
Signed-off-by: Tariq Toukan <tariqt@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
c1d5f8ff80
commit
61b6034c6c
|
@ -245,13 +245,9 @@ static u32 freq_to_shift(u16 freq)
|
||||||
{
|
{
|
||||||
u32 freq_khz = freq * 1000;
|
u32 freq_khz = freq * 1000;
|
||||||
u64 max_val_cycles = freq_khz * 1000 * MLX4_EN_WRAP_AROUND_SEC;
|
u64 max_val_cycles = freq_khz * 1000 * MLX4_EN_WRAP_AROUND_SEC;
|
||||||
u64 tmp_rounded =
|
u64 max_val_cycles_rounded = 1ULL << fls64(max_val_cycles - 1);
|
||||||
roundup_pow_of_two(max_val_cycles) > max_val_cycles ?
|
|
||||||
roundup_pow_of_two(max_val_cycles) - 1 : UINT_MAX;
|
|
||||||
u64 max_val_cycles_rounded = is_power_of_2(max_val_cycles + 1) ?
|
|
||||||
max_val_cycles : tmp_rounded;
|
|
||||||
/* calculate max possible multiplier in order to fit in 64bit */
|
/* calculate max possible multiplier in order to fit in 64bit */
|
||||||
u64 max_mul = div_u64(0xffffffffffffffffULL, max_val_cycles_rounded);
|
u64 max_mul = div64_u64(ULLONG_MAX, max_val_cycles_rounded);
|
||||||
|
|
||||||
/* This comes from the reverse of clocksource_khz2mult */
|
/* This comes from the reverse of clocksource_khz2mult */
|
||||||
return ilog2(div_u64(max_mul * freq_khz, 1000000));
|
return ilog2(div_u64(max_mul * freq_khz, 1000000));
|
||||||
|
|