iio: adc: sc27xx: Add ADC data conversion timeout

Sometimes the ADC controller met some problems, and it will not complete
the data conversion, that will can not wake up the read process any more
to block users. So we should add one maximum conversion time to avoid
this issue.

Signed-off-by: Freeman Liu <freeman.liu@unisoc.com>
Signed-off-by: Baolin Wang <baolin.wang@linaro.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
Freeman Liu 2018-11-09 11:25:31 +08:00 committed by Jonathan Cameron
parent befa9f6a3e
commit 750ac07eb2
1 changed files with 11 additions and 1 deletions

View File

@ -52,6 +52,9 @@
/* Timeout (ms) for the trylock of hardware spinlocks */
#define SC27XX_ADC_HWLOCK_TIMEOUT 5000
/* Timeout (ms) for ADC data conversion according to ADC datasheet */
#define SC27XX_ADC_RDY_TIMEOUT 100
/* Maximum ADC channel number */
#define SC27XX_ADC_CHANNEL_MAX 32
@ -223,7 +226,14 @@ static int sc27xx_adc_read(struct sc27xx_adc_data *data, int channel,
if (ret)
goto disable_adc;
wait_for_completion(&data->completion);
ret = wait_for_completion_timeout(&data->completion,
msecs_to_jiffies(SC27XX_ADC_RDY_TIMEOUT));
if (!ret) {
dev_err(data->dev, "read ADC data timeout\n");
ret = -ETIMEDOUT;
} else {
ret = 0;
}
disable_adc:
regmap_update_bits(data->regmap, data->base + SC27XX_ADC_CTL,