wimax/i2400m: Fix potential urb refcnt leak
i2400mu_bus_bm_wait_for_ack() invokes usb_get_urb(), which increases the refcount of the "notif_urb". When i2400mu_bus_bm_wait_for_ack() returns, local variable "notif_urb" becomes invalid, so the refcount should be decreased to keep refcount balanced. The issue happens in all paths of i2400mu_bus_bm_wait_for_ack(), which forget to decrease the refcnt increased by usb_get_urb(), causing a refcnt leak. Fix this issue by calling usb_put_urb() before the i2400mu_bus_bm_wait_for_ack() returns. Signed-off-by: Xiyu Yang <xiyuyang19@fudan.edu.cn> Signed-off-by: Xin Tan <tanxin.ctf@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
de05842076
commit
7717cbec17
|
@ -354,6 +354,7 @@ ssize_t i2400mu_bus_bm_wait_for_ack(struct i2400m *i2400m,
|
|||
usb_autopm_put_interface(i2400mu->usb_iface);
|
||||
d_fnend(8, dev, "(i2400m %p ack %p size %zu) = %ld\n",
|
||||
i2400m, ack, ack_size, (long) result);
|
||||
usb_put_urb(¬if_urb);
|
||||
return result;
|
||||
|
||||
error_exceeded:
|
||||
|
|