s390/cpum_sf: Add data entry sizes to sampling trailer entry
The CPU Measurement sampling facility creates a trailer entry for each
Sample-Data-Block of stored samples. The trailer entry contains the sizes
(in bytes) of the stored sampling types:
- basic-sampling data entry size
- diagnostic-sampling data entry size
Both sizes are 2 bytes long.
This patch changes the trailer entry definition to reflect this.
Fixes: fcc77f5073
("s390/cpum_sf: Atomically reset trailer entry fields of sample-data-blocks")
Signed-off-by: Thomas Richter <tmricht@linux.ibm.com>
Reviewed-by: Hendrik Brueckner <brueckner@linux.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
This commit is contained in:
parent
3c0a83b14e
commit
77715b7ddb
|
@ -129,7 +129,9 @@ struct hws_trailer_entry {
|
|||
unsigned int f:1; /* 0 - Block Full Indicator */
|
||||
unsigned int a:1; /* 1 - Alert request control */
|
||||
unsigned int t:1; /* 2 - Timestamp format */
|
||||
unsigned long long:61; /* 3 - 63: Reserved */
|
||||
unsigned int :29; /* 3 - 31: Reserved */
|
||||
unsigned int bsdes:16; /* 32-47: size of basic SDE */
|
||||
unsigned int dsdes:16; /* 48-63: size of diagnostic SDE */
|
||||
};
|
||||
unsigned long long flags; /* 0 - 63: All indicators */
|
||||
};
|
||||
|
|
Loading…