serial: exar: Fix feature control register constants
According to the XR17V352 manual, bit 4 is IrDA control and bit 5 for 485. Fortunately, no driver used them so far. Signed-off-by: Jan Kiszka <jan.kiszka@siemens.com> Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
parent
5b5f252d67
commit
7795753661
|
@ -374,8 +374,8 @@
|
|||
#define UART_EXAR_DVID 0x8d /* Device identification */
|
||||
|
||||
#define UART_EXAR_FCTR 0x08 /* Feature Control Register */
|
||||
#define UART_FCTR_EXAR_IRDA 0x08 /* IrDa data encode select */
|
||||
#define UART_FCTR_EXAR_485 0x10 /* Auto 485 half duplex dir ctl */
|
||||
#define UART_FCTR_EXAR_IRDA 0x10 /* IrDa data encode select */
|
||||
#define UART_FCTR_EXAR_485 0x20 /* Auto 485 half duplex dir ctl */
|
||||
#define UART_FCTR_EXAR_TRGA 0x00 /* FIFO trigger table A */
|
||||
#define UART_FCTR_EXAR_TRGB 0x60 /* FIFO trigger table B */
|
||||
#define UART_FCTR_EXAR_TRGC 0x80 /* FIFO trigger table C */
|
||||
|
|
Loading…
Reference in New Issue