dcdbas.txt: standardize document format
Each text file under Documentation follows a different format. Some doesn't even have titles! Change its representation to follow the adopted standard, using ReST markups for it to be parseable by Sphinx: - Mark titles; - Mark literal blocks; - Mark table. Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com> Signed-off-by: Jonathan Corbet <corbet@lwn.net>
This commit is contained in:
parent
2e4e6f30f7
commit
7effa5b0e8
|
@ -1,4 +1,9 @@
|
|||
===================================
|
||||
Dell Systems Management Base Driver
|
||||
===================================
|
||||
|
||||
Overview
|
||||
========
|
||||
|
||||
The Dell Systems Management Base Driver provides a sysfs interface for
|
||||
systems management software such as Dell OpenManage to perform system
|
||||
|
@ -17,6 +22,7 @@ more information about the libsmbios project.
|
|||
|
||||
|
||||
System Management Interrupt
|
||||
===========================
|
||||
|
||||
On some Dell systems, systems management software must access certain
|
||||
management information via a system management interrupt (SMI). The SMI data
|
||||
|
@ -24,12 +30,12 @@ buffer must reside in 32-bit address space, and the physical address of the
|
|||
buffer is required for the SMI. The driver maintains the memory required for
|
||||
the SMI and provides a way for the application to generate the SMI.
|
||||
The driver creates the following sysfs entries for systems management
|
||||
software to perform these system management interrupts:
|
||||
software to perform these system management interrupts::
|
||||
|
||||
/sys/devices/platform/dcdbas/smi_data
|
||||
/sys/devices/platform/dcdbas/smi_data_buf_phys_addr
|
||||
/sys/devices/platform/dcdbas/smi_data_buf_size
|
||||
/sys/devices/platform/dcdbas/smi_request
|
||||
/sys/devices/platform/dcdbas/smi_data
|
||||
/sys/devices/platform/dcdbas/smi_data_buf_phys_addr
|
||||
/sys/devices/platform/dcdbas/smi_data_buf_size
|
||||
/sys/devices/platform/dcdbas/smi_request
|
||||
|
||||
Systems management software must perform the following steps to execute
|
||||
a SMI using this driver:
|
||||
|
@ -43,6 +49,7 @@ a SMI using this driver:
|
|||
|
||||
|
||||
Host Control Action
|
||||
===================
|
||||
|
||||
Dell OpenManage supports a host control feature that allows the administrator
|
||||
to perform a power cycle or power off of the system after the OS has finished
|
||||
|
@ -69,12 +76,14 @@ power off host control action using this driver:
|
|||
|
||||
|
||||
Host Control SMI Type
|
||||
=====================
|
||||
|
||||
The following table shows the value to write to host_control_smi_type to
|
||||
perform a power cycle or power off host control action:
|
||||
|
||||
=================== =====================
|
||||
PowerEdge System Host Control SMI Type
|
||||
---------------- ---------------------
|
||||
=================== =====================
|
||||
300 HC_SMITYPE_TYPE1
|
||||
1300 HC_SMITYPE_TYPE1
|
||||
1400 HC_SMITYPE_TYPE2
|
||||
|
@ -87,5 +96,4 @@ PowerEdge System Host Control SMI Type
|
|||
1655MC HC_SMITYPE_TYPE2
|
||||
700 HC_SMITYPE_TYPE3
|
||||
750 HC_SMITYPE_TYPE3
|
||||
|
||||
|
||||
=================== =====================
|
||||
|
|