powerpc/pseries: Query hypervisor for RFI flush settings
A new hypervisor call is available which tells the guest settings related to the RFI flush. Use it to query the appropriate flush instruction(s), and whether the flush is required. Signed-off-by: Michael Neuling <mikey@neuling.org> Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>
This commit is contained in:
parent
bc9c9304a4
commit
8989d56878
|
@ -459,6 +459,39 @@ static void __init find_and_init_phbs(void)
|
|||
of_pci_check_probe_only();
|
||||
}
|
||||
|
||||
static void pseries_setup_rfi_flush(void)
|
||||
{
|
||||
struct h_cpu_char_result result;
|
||||
enum l1d_flush_type types;
|
||||
bool enable;
|
||||
long rc;
|
||||
|
||||
/* Enable by default */
|
||||
enable = true;
|
||||
|
||||
rc = plpar_get_cpu_characteristics(&result);
|
||||
if (rc == H_SUCCESS) {
|
||||
types = L1D_FLUSH_NONE;
|
||||
|
||||
if (result.character & H_CPU_CHAR_L1D_FLUSH_TRIG2)
|
||||
types |= L1D_FLUSH_MTTRIG;
|
||||
if (result.character & H_CPU_CHAR_L1D_FLUSH_ORI30)
|
||||
types |= L1D_FLUSH_ORI;
|
||||
|
||||
/* Use fallback if nothing set in hcall */
|
||||
if (types == L1D_FLUSH_NONE)
|
||||
types = L1D_FLUSH_FALLBACK;
|
||||
|
||||
if (!(result.behaviour & H_CPU_BEHAV_L1D_FLUSH_PR))
|
||||
enable = false;
|
||||
} else {
|
||||
/* Default to fallback if case hcall is not available */
|
||||
types = L1D_FLUSH_FALLBACK;
|
||||
}
|
||||
|
||||
setup_rfi_flush(types, enable);
|
||||
}
|
||||
|
||||
static void __init pSeries_setup_arch(void)
|
||||
{
|
||||
set_arch_panic_timeout(10, ARCH_PANIC_TIMEOUT);
|
||||
|
@ -476,6 +509,8 @@ static void __init pSeries_setup_arch(void)
|
|||
|
||||
fwnmi_init();
|
||||
|
||||
pseries_setup_rfi_flush();
|
||||
|
||||
/* By default, only probe PCI (can be overridden by rtas_pci) */
|
||||
pci_add_flags(PCI_PROBE_ONLY);
|
||||
|
||||
|
|
Loading…
Reference in New Issue