scsi: ufs: Fix kernel-doc errors and warnings

Avoid that the kernel-doc tool complains about mismatches between
kernel-doc headers and function definitions. Avoid that errors like the
following are reported when building the UFS driver with W=1:

drivers/scsi/ufs/tc-dwc-g210-pci.c:60: error: Cannot parse struct or union!
drivers/scsi/ufs/tc-dwc-g210-pltfrm.c:26: warning: cannot understand function prototype: 'struct ufs_hba_variant_ops tc_dwc_g210_20bit_pltfm_hba_vops = '

Signed-off-by: Bart Van Assche <bart.vanassche@wdc.com>
Cc: Vivek Gautam <vivek.gautam@codeaurora.org>
Cc: Stanislav Nijnikov <stanislav.nijnikov@wdc.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
This commit is contained in:
Bart Van Assche 2018-03-01 15:07:20 -08:00 committed by Martin K. Petersen
parent e0b14a4ad5
commit 8aa29f192c
4 changed files with 52 additions and 55 deletions

View File

@ -51,7 +51,7 @@ static int tc_dwc_g210_pci_runtime_idle(struct device *dev)
return ufshcd_runtime_idle(dev_get_drvdata(dev));
}
/**
/*
* struct ufs_hba_dwc_vops - UFS DWC specific variant operations
*/
static struct ufs_hba_variant_ops tc_dwc_g210_pci_hba_vops = {
@ -71,7 +71,7 @@ static void tc_dwc_g210_pci_shutdown(struct pci_dev *pdev)
/**
* tc_dwc_g210_pci_remove - de-allocate PCI/SCSI host and host memory space
* data structure memory
* @pdev - pointer to PCI handle
* @pdev: pointer to PCI handle
*/
static void tc_dwc_g210_pci_remove(struct pci_dev *pdev)
{

View File

@ -20,7 +20,7 @@
#include "ufshcd-dwc.h"
#include "tc-dwc-g210.h"
/**
/*
* UFS DWC specific variant operations
*/
static struct ufs_hba_variant_ops tc_dwc_g210_20bit_pltfm_hba_vops = {

View File

@ -75,8 +75,7 @@ static struct ufs_hba_variant_ops ufs_intel_cnl_hba_vops = {
#ifdef CONFIG_PM_SLEEP
/**
* ufshcd_pci_suspend - suspend power management function
* @pdev: pointer to PCI device handle
* @state: power state
* @dev: pointer to PCI device handle
*
* Returns 0 if successful
* Returns non-zero otherwise
@ -88,7 +87,7 @@ static int ufshcd_pci_suspend(struct device *dev)
/**
* ufshcd_pci_resume - resume power management function
* @pdev: pointer to PCI device handle
* @dev: pointer to PCI device handle
*
* Returns 0 if successful
* Returns non-zero otherwise
@ -126,7 +125,7 @@ static void ufshcd_pci_shutdown(struct pci_dev *pdev)
/**
* ufshcd_pci_remove - de-allocate PCI/SCSI host and host memory space
* data structure memory
* @pdev - pointer to PCI handle
* @pdev: pointer to PCI handle
*/
static void ufshcd_pci_remove(struct pci_dev *pdev)
{

View File

@ -524,7 +524,7 @@ int ufshcd_wait_for_register(struct ufs_hba *hba, u32 reg, u32 mask,
/**
* ufshcd_get_intr_mask - Get the interrupt bit mask
* @hba - Pointer to adapter instance
* @hba: Pointer to adapter instance
*
* Returns interrupt bit mask per version
*/
@ -551,7 +551,7 @@ static inline u32 ufshcd_get_intr_mask(struct ufs_hba *hba)
/**
* ufshcd_get_ufs_version - Get the UFS version supported by the HBA
* @hba - Pointer to adapter instance
* @hba: Pointer to adapter instance
*
* Returns UFSHCI version supported by the controller
*/
@ -578,7 +578,7 @@ static inline bool ufshcd_is_device_present(struct ufs_hba *hba)
/**
* ufshcd_get_tr_ocs - Get the UTRD Overall Command Status
* @lrb: pointer to local command reference block
* @lrbp: pointer to local command reference block
*
* This function is used to get the OCS field from UTRD
* Returns the OCS field in the UTRD
@ -1738,7 +1738,7 @@ void ufshcd_send_command(struct ufs_hba *hba, unsigned int task_tag)
/**
* ufshcd_copy_sense_data - Copy sense data in case of check condition
* @lrb - pointer to local reference block
* @lrbp: pointer to local reference block
*/
static inline void ufshcd_copy_sense_data(struct ufshcd_lrb *lrbp)
{
@ -1760,7 +1760,7 @@ static inline void ufshcd_copy_sense_data(struct ufshcd_lrb *lrbp)
* ufshcd_copy_query_response() - Copy the Query Response and the data
* descriptor
* @hba: per adapter instance
* @lrb - pointer to local reference block
* @lrbp: pointer to local reference block
*/
static
int ufshcd_copy_query_response(struct ufs_hba *hba, struct ufshcd_lrb *lrbp)
@ -1861,7 +1861,7 @@ ufshcd_dispatch_uic_cmd(struct ufs_hba *hba, struct uic_command *uic_cmd)
/**
* ufshcd_wait_for_uic_cmd - Wait complectioin of UIC command
* @hba: per adapter instance
* @uic_command: UIC command
* @uic_cmd: UIC command
*
* Must be called with mutex held.
* Returns 0 only if success.
@ -1944,7 +1944,8 @@ ufshcd_send_uic_cmd(struct ufs_hba *hba, struct uic_command *uic_cmd)
/**
* ufshcd_map_sg - Map scatter-gather list to prdt
* @lrbp - pointer to local reference block
* @hba: per adapter instance
* @lrbp: pointer to local reference block
*
* Returns 0 in case of success, non-zero value in case of failure
*/
@ -2080,8 +2081,8 @@ static void ufshcd_prepare_req_desc_hdr(struct ufshcd_lrb *lrbp,
/**
* ufshcd_prepare_utp_scsi_cmd_upiu() - fills the utp_transfer_req_desc,
* for scsi commands
* @lrbp - local reference block pointer
* @upiu_flags - flags
* @lrbp: local reference block pointer
* @upiu_flags: flags
*/
static
void ufshcd_prepare_utp_scsi_cmd_upiu(struct ufshcd_lrb *lrbp, u32 upiu_flags)
@ -2169,8 +2170,8 @@ static inline void ufshcd_prepare_utp_nop_upiu(struct ufshcd_lrb *lrbp)
/**
* ufshcd_comp_devman_upiu - UFS Protocol Information Unit(UPIU)
* for Device Management Purposes
* @hba - per adapter instance
* @lrb - pointer to local reference block
* @hba: per adapter instance
* @lrbp: pointer to local reference block
*/
static int ufshcd_comp_devman_upiu(struct ufs_hba *hba, struct ufshcd_lrb *lrbp)
{
@ -2197,8 +2198,8 @@ static int ufshcd_comp_devman_upiu(struct ufs_hba *hba, struct ufshcd_lrb *lrbp)
/**
* ufshcd_comp_scsi_upiu - UFS Protocol Information Unit(UPIU)
* for SCSI Purposes
* @hba - per adapter instance
* @lrb - pointer to local reference block
* @hba: per adapter instance
* @lrbp: pointer to local reference block
*/
static int ufshcd_comp_scsi_upiu(struct ufs_hba *hba, struct ufshcd_lrb *lrbp)
{
@ -2224,7 +2225,7 @@ static int ufshcd_comp_scsi_upiu(struct ufs_hba *hba, struct ufshcd_lrb *lrbp)
/**
* ufshcd_upiu_wlun_to_scsi_wlun - maps UPIU W-LUN id to SCSI W-LUN ID
* @scsi_lun: UPIU W-LUN id
* @upiu_wlun_id: UPIU W-LUN id
*
* Returns SCSI W-LUN id
*/
@ -2235,8 +2236,8 @@ static inline u16 ufshcd_upiu_wlun_to_scsi_wlun(u8 upiu_wlun_id)
/**
* ufshcd_queuecommand - main entry point for SCSI requests
* @host: SCSI host pointer
* @cmd: command from SCSI Midlayer
* @done: call back function
*
* Returns 0 for success, non-zero in case of failure
*/
@ -2477,7 +2478,7 @@ static int ufshcd_wait_for_dev_cmd(struct ufs_hba *hba,
/**
* ufshcd_get_dev_cmd_tag - Get device management command tag
* @hba: per-adapter instance
* @tag: pointer to variable with available slot value
* @tag_out: pointer to variable with available slot value
*
* Get a free slot and lock it until device management command
* completes.
@ -2514,9 +2515,9 @@ static inline void ufshcd_put_dev_cmd_tag(struct ufs_hba *hba, int tag)
/**
* ufshcd_exec_dev_cmd - API for sending device management requests
* @hba - UFS hba
* @cmd_type - specifies the type (NOP, Query...)
* @timeout - time in seconds
* @hba: UFS hba
* @cmd_type: specifies the type (NOP, Query...)
* @timeout: time in seconds
*
* NOTE: Since there is only one available tag for device management commands,
* it is expected you hold the hba->dev_cmd.lock mutex.
@ -2613,10 +2614,10 @@ static int ufshcd_query_flag_retry(struct ufs_hba *hba,
/**
* ufshcd_query_flag() - API function for sending flag query requests
* hba: per-adapter instance
* query_opcode: flag query to perform
* idn: flag idn to access
* flag_res: the flag value after the query request completes
* @hba: per-adapter instance
* @opcode: flag query to perform
* @idn: flag idn to access
* @flag_res: the flag value after the query request completes
*
* Returns 0 for success, non-zero in case of failure
*/
@ -2680,12 +2681,12 @@ int ufshcd_query_flag(struct ufs_hba *hba, enum query_opcode opcode,
/**
* ufshcd_query_attr - API function for sending attribute requests
* hba: per-adapter instance
* opcode: attribute opcode
* idn: attribute idn to access
* index: index field
* selector: selector field
* attr_val: the attribute value after the query request completes
* @hba: per-adapter instance
* @opcode: attribute opcode
* @idn: attribute idn to access
* @index: index field
* @selector: selector field
* @attr_val: the attribute value after the query request completes
*
* Returns 0 for success, non-zero in case of failure
*/
@ -2844,15 +2845,14 @@ static int __ufshcd_query_descriptor(struct ufs_hba *hba,
}
/**
* ufshcd_query_descriptor_retry - API function for sending descriptor
* requests
* hba: per-adapter instance
* opcode: attribute opcode
* idn: attribute idn to access
* index: index field
* selector: selector field
* desc_buf: the buffer that contains the descriptor
* buf_len: length parameter passed to the device
* ufshcd_query_descriptor_retry - API function for sending descriptor requests
* @hba: per-adapter instance
* @opcode: attribute opcode
* @idn: attribute idn to access
* @index: index field
* @selector: selector field
* @desc_buf: the buffer that contains the descriptor
* @buf_len: length parameter passed to the device
*
* Returns 0 for success, non-zero in case of failure.
* The buf_len parameter will contain, on return, the length parameter
@ -3077,7 +3077,6 @@ static int ufshcd_read_device_desc(struct ufs_hba *hba, u8 *buf, u32 size)
*
* Return 0 in case of success, non-zero otherwise
*/
#define ASCII_STD true
int ufshcd_read_string_desc(struct ufs_hba *hba, int desc_index,
u8 *buf, u32 size, bool ascii)
{
@ -3879,7 +3878,7 @@ static int ufshcd_config_pwr_mode(struct ufs_hba *hba,
/**
* ufshcd_complete_dev_init() - checks device readiness
* hba: per-adapter instance
* @hba: per-adapter instance
*
* Set fDeviceInit flag and poll until device toggles it.
*/
@ -4418,7 +4417,7 @@ static int ufshcd_task_req_compl(struct ufs_hba *hba, u32 index, u8 *resp)
/**
* ufshcd_scsi_cmd_status - Update SCSI command result based on SCSI status
* @lrb: pointer to local reference block of completed command
* @lrbp: pointer to local reference block of completed command
* @scsi_status: SCSI command status
*
* Returns value base on SCSI command status
@ -4453,7 +4452,7 @@ ufshcd_scsi_cmd_status(struct ufshcd_lrb *lrbp, int scsi_status)
/**
* ufshcd_transfer_rsp_status - Get overall status of the response
* @hba: per adapter instance
* @lrb: pointer to local reference block of completed command
* @lrbp: pointer to local reference block of completed command
*
* Returns result of the command to notify SCSI midlayer
*/
@ -5761,7 +5760,7 @@ static int ufshcd_reset_and_restore(struct ufs_hba *hba)
/**
* ufshcd_eh_host_reset_handler - host reset handler registered to scsi layer
* @cmd - SCSI command pointer
* @cmd: SCSI command pointer
*
* Returns SUCCESS/FAILED
*/
@ -5946,11 +5945,11 @@ static void ufshcd_init_icc_levels(struct ufs_hba *hba)
* will take effect only when its sent to "UFS device" well known logical unit
* hence we require the scsi_device instance to represent this logical unit in
* order for the UFS host driver to send the SSU command for power management.
*
* We also require the scsi_device instance for "RPMB" (Replay Protected Memory
* Block) LU so user space process can control this LU. User space may also
* want to have access to BOOT LU.
*
* This function adds scsi device instances for each of all well known LUs
* (except "REPORT LUNS" LU).
*
@ -6019,7 +6018,7 @@ static int ufs_get_device_desc(struct ufs_hba *hba,
model_index = desc_buf[DEVICE_DESC_PARAM_PRDCT_NAME];
err = ufshcd_read_string_desc(hba, model_index, str_desc_buf,
QUERY_DESC_MAX_SIZE, ASCII_STD);
QUERY_DESC_MAX_SIZE, true/*ASCII*/);
if (err) {
dev_err(hba->dev, "%s: Failed reading Product Name. err = %d\n",
__func__, err);
@ -7413,7 +7412,6 @@ static int ufshcd_resume(struct ufs_hba *hba, enum ufs_pm_op pm_op)
/**
* ufshcd_system_suspend - system suspend routine
* @hba: per adapter instance
* @pm_op: runtime PM or system PM
*
* Check the description of ufshcd_suspend() function for more details.
*
@ -7597,7 +7595,7 @@ EXPORT_SYMBOL(ufshcd_shutdown);
/**
* ufshcd_remove - de-allocate SCSI host and host memory space
* data structure memory
* @hba - per adapter instance
* @hba: per adapter instance
*/
void ufshcd_remove(struct ufs_hba *hba)
{