pwm: omap-dmtimer: Add debug message for effective period and duty cycle

After going through the math and constraints checking to compute load
and match values, it is helpful to know what the resultant period and
duty cycle are.

Signed-off-by: David Rivshin <drivshin@allworx.com>
Acked-by: Neil Armstrong <narmstrong@baylibre.com>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
This commit is contained in:
David Rivshin 2016-01-29 23:26:54 -05:00 committed by Thierry Reding
parent 7b0883f338
commit 922201d129
1 changed files with 8 additions and 1 deletions

View File

@ -102,7 +102,8 @@ static int pwm_omap_dmtimer_config(struct pwm_chip *chip,
unsigned long clk_rate;
bool timer_active;
dev_dbg(chip->dev, "duty cycle: %d, period %d\n", duty_ns, period_ns);
dev_dbg(chip->dev, "requested duty cycle: %d ns, period: %d ns\n",
duty_ns, period_ns);
mutex_lock(&omap->mutex);
if (duty_ns == pwm_get_duty_cycle(pwm) &&
@ -166,6 +167,12 @@ static int pwm_omap_dmtimer_config(struct pwm_chip *chip,
duty_cycles = period_cycles - 1;
}
dev_dbg(chip->dev, "effective duty cycle: %lld ns, period: %lld ns\n",
DIV_ROUND_CLOSEST_ULL((u64)NSEC_PER_SEC * duty_cycles,
clk_rate),
DIV_ROUND_CLOSEST_ULL((u64)NSEC_PER_SEC * period_cycles,
clk_rate));
load_value = (DM_TIMER_MAX - period_cycles) + 1;
match_value = load_value + duty_cycles - 1;