net: phy: fixed: return an error for Clause 45 over 22 reads

The fixed PHY driver does not properly emulate Clause 45 over Clause 22
MDIO reads, and as such, will return bogus values when we access such
registers.

Return an error when accessing these registers in order to prevent
advertising bogus capabilities such as EEE support and such.

Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Florian Fainelli 2014-08-22 18:55:42 -07:00 committed by David S. Miller
parent 9df54ddab9
commit a2dbba7674
1 changed files with 11 additions and 0 deletions

View File

@ -124,6 +124,17 @@ static int fixed_mdio_read(struct mii_bus *bus, int phy_addr, int reg_num)
if (reg_num >= MII_REGS_NUM)
return -1;
/* We do not support emulating Clause 45 over Clause 22 register reads
* return an error instead of bogus data.
*/
switch (reg_num) {
case MII_MMD_CTRL:
case MII_MMD_DATA:
return -1;
default:
break;
}
list_for_each_entry(fp, &fmb->phys, node) {
if (fp->addr == phy_addr) {
/* Issue callback if user registered it. */