From a661b1d9936e77a6c07f8ca10e3494932fa5e2c8 Mon Sep 17 00:00:00 2001 From: Axel Lin Date: Fri, 22 Feb 2019 00:28:31 +0800 Subject: [PATCH] regulator: mt6311: Use linear instead of linear range for mt6311_buck_ops Current code already set .min_uV and .uV_step fields and it actually can use regulator_list_voltage_linear. So remove buck_volt_range and use regulator_list_voltage_linear instead. Signed-off-by: Axel Lin Signed-off-by: Mark Brown --- drivers/regulator/mt6311-regulator.c | 10 ++-------- 1 file changed, 2 insertions(+), 8 deletions(-) diff --git a/drivers/regulator/mt6311-regulator.c b/drivers/regulator/mt6311-regulator.c index 0495716fd35f..01d69f43d2b0 100644 --- a/drivers/regulator/mt6311-regulator.c +++ b/drivers/regulator/mt6311-regulator.c @@ -38,13 +38,9 @@ static const struct regmap_config mt6311_regmap_config = { #define MT6311_MAX_UV 1393750 #define MT6311_STEP_UV 6250 -static const struct regulator_linear_range buck_volt_range[] = { - REGULATOR_LINEAR_RANGE(MT6311_MIN_UV, 0, 0x7f, MT6311_STEP_UV), -}; - static const struct regulator_ops mt6311_buck_ops = { - .list_voltage = regulator_list_voltage_linear_range, - .map_voltage = regulator_map_voltage_linear_range, + .list_voltage = regulator_list_voltage_linear, + .map_voltage = regulator_map_voltage_linear, .set_voltage_sel = regulator_set_voltage_sel_regmap, .get_voltage_sel = regulator_get_voltage_sel_regmap, .set_voltage_time_sel = regulator_set_voltage_time_sel, @@ -71,8 +67,6 @@ static const struct regulator_ops mt6311_ldo_ops = { .min_uV = MT6311_MIN_UV,\ .uV_step = MT6311_STEP_UV,\ .owner = THIS_MODULE,\ - .linear_ranges = buck_volt_range, \ - .n_linear_ranges = ARRAY_SIZE(buck_volt_range), \ .enable_reg = MT6311_VDVFS11_CON9,\ .enable_mask = MT6311_PMIC_VDVFS11_EN_MASK,\ .vsel_reg = MT6311_VDVFS11_CON12,\