iio: dht11: Improve detection of sensor type
The old code was based on a DHT11 datasheet which specifies a measurement range of 20%-90% RH. Turns out the sensor actually reports values outside this range, so we should support it as far as possible. Reported-by: Edward Attfield <edward@attfield.ca> Signed-off-by: Harald Geyer <harald@ccbib.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
7fe2241c0e
commit
a6bffb6920
|
@ -159,7 +159,7 @@ static int dht11_decode(struct dht11 *dht11, int offset)
|
|||
}
|
||||
|
||||
dht11->timestamp = ktime_get_boot_ns();
|
||||
if (hum_int < 20) { /* DHT22 */
|
||||
if (hum_int < 4) { /* DHT22: 100000 = (3*256+232)*100 */
|
||||
dht11->temperature = (((temp_int & 0x7f) << 8) + temp_dec) *
|
||||
((temp_int & 0x80) ? -100 : 100);
|
||||
dht11->humidity = ((hum_int << 8) + hum_dec) * 100;
|
||||
|
|