thunderbolt: Deactivate all paths before restarting them

State of the connected devices and tunnel configuration is not known
during resume. For example some paths may not be complete anymore if the
user has unplugged the related devices. So instead of marking all paths
as inactive we go ahead and deactivate them explicitly before we restart
them.

Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
This commit is contained in:
Mika Westerberg 2017-02-19 23:37:35 +02:00
parent 8c7acaaf02
commit aae9e27f3b
1 changed files with 11 additions and 1 deletions

View File

@ -185,8 +185,18 @@ int tb_tunnel_restart(struct tb_tunnel *tunnel)
tb_tunnel_info(tunnel, "activating\n");
/*
* Make sure all paths are properly disabled before enabling
* them again.
*/
for (i = 0; i < tunnel->npaths; i++) {
if (tunnel->paths[i]->activated) {
tb_path_deactivate(tunnel->paths[i]);
tunnel->paths[i]->activated = false;
}
}
for (i = 0; i < tunnel->npaths; i++) {
res = tb_path_activate(tunnel->paths[i]);
if (res)
goto err;