powerpc/pseries/eeh: Refactor the configure_bridge RTAS tokens
The RTAS calls "ibm,configure-pe" and "ibm,configure-bridge" perform the same actions, however the former can skip configuration if unnecessary. The existing code treats them as different tokens even though only one will ever be called. Refactor this by making a single token that is assigned during init. Signed-off-by: Russell Currey <ruscur@russell.cc> Acked-by: Gavin Shan <gwshan@linux.vnet.ibm.com> Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>
This commit is contained in:
parent
871e178e0f
commit
bd000b82e8
|
@ -53,7 +53,6 @@ static int ibm_read_slot_reset_state2;
|
|||
static int ibm_slot_error_detail;
|
||||
static int ibm_get_config_addr_info;
|
||||
static int ibm_get_config_addr_info2;
|
||||
static int ibm_configure_bridge;
|
||||
static int ibm_configure_pe;
|
||||
|
||||
/*
|
||||
|
@ -81,7 +80,14 @@ static int pseries_eeh_init(void)
|
|||
ibm_get_config_addr_info2 = rtas_token("ibm,get-config-addr-info2");
|
||||
ibm_get_config_addr_info = rtas_token("ibm,get-config-addr-info");
|
||||
ibm_configure_pe = rtas_token("ibm,configure-pe");
|
||||
ibm_configure_bridge = rtas_token("ibm,configure-bridge");
|
||||
|
||||
/*
|
||||
* ibm,configure-pe and ibm,configure-bridge have the same semantics,
|
||||
* however ibm,configure-pe can be faster. If we can't find
|
||||
* ibm,configure-pe then fall back to using ibm,configure-bridge.
|
||||
*/
|
||||
if (ibm_configure_pe == RTAS_UNKNOWN_SERVICE)
|
||||
ibm_configure_pe = rtas_token("ibm,configure-bridge");
|
||||
|
||||
/*
|
||||
* Necessary sanity check. We needn't check "get-config-addr-info"
|
||||
|
@ -93,8 +99,7 @@ static int pseries_eeh_init(void)
|
|||
(ibm_read_slot_reset_state2 == RTAS_UNKNOWN_SERVICE &&
|
||||
ibm_read_slot_reset_state == RTAS_UNKNOWN_SERVICE) ||
|
||||
ibm_slot_error_detail == RTAS_UNKNOWN_SERVICE ||
|
||||
(ibm_configure_pe == RTAS_UNKNOWN_SERVICE &&
|
||||
ibm_configure_bridge == RTAS_UNKNOWN_SERVICE)) {
|
||||
ibm_configure_pe == RTAS_UNKNOWN_SERVICE) {
|
||||
pr_info("EEH functionality not supported\n");
|
||||
return -EINVAL;
|
||||
}
|
||||
|
@ -624,18 +629,9 @@ static int pseries_eeh_configure_bridge(struct eeh_pe *pe)
|
|||
config_addr = pe->addr;
|
||||
|
||||
while (max_wait > 0) {
|
||||
/* Use new configure-pe function, if supported */
|
||||
if (ibm_configure_pe != RTAS_UNKNOWN_SERVICE) {
|
||||
ret = rtas_call(ibm_configure_pe, 3, 1, NULL,
|
||||
config_addr, BUID_HI(pe->phb->buid),
|
||||
BUID_LO(pe->phb->buid));
|
||||
} else if (ibm_configure_bridge != RTAS_UNKNOWN_SERVICE) {
|
||||
ret = rtas_call(ibm_configure_bridge, 3, 1, NULL,
|
||||
config_addr, BUID_HI(pe->phb->buid),
|
||||
BUID_LO(pe->phb->buid));
|
||||
} else {
|
||||
return -EFAULT;
|
||||
}
|
||||
ret = rtas_call(ibm_configure_pe, 3, 1, NULL,
|
||||
config_addr, BUID_HI(pe->phb->buid),
|
||||
BUID_LO(pe->phb->buid));
|
||||
|
||||
if (!ret)
|
||||
return ret;
|
||||
|
|
Loading…
Reference in New Issue