power: supply: axp288_fuel_gauge: Optimize get_current()
First check the discharge current, and when that is non 0 use that without also checking the charge current (which will be 0 then). This makes get_current() do only 1 i2c read instead of 2 when on battery. This is esp. important given the pmic i2c bus mutex stuff used on boards with an axp288 because the SoC's own punit also may access the axp288, which makes i2c accesses more expensive then normal. Signed-off-by: Hans de Goede <hdegoede@redhat.com> Reviewed-by: Chen-Yu Tsai <wens@csie.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
This commit is contained in:
parent
2b5a4b4bf2
commit
ceb40831c9
|
@ -386,24 +386,19 @@ static int fuel_gauge_get_vbatt(struct axp288_fg_info *info, int *vbatt)
|
|||
|
||||
static int fuel_gauge_get_current(struct axp288_fg_info *info, int *cur)
|
||||
{
|
||||
int ret, value = 0;
|
||||
int charge, discharge;
|
||||
int ret, discharge;
|
||||
|
||||
ret = iio_read_channel_raw(info->iio_channel[BAT_CHRG_CURR], &charge);
|
||||
if (ret < 0)
|
||||
goto current_read_fail;
|
||||
/* First check discharge current, so that we do only 1 read on bat. */
|
||||
ret = iio_read_channel_raw(info->iio_channel[BAT_D_CURR], &discharge);
|
||||
if (ret < 0)
|
||||
goto current_read_fail;
|
||||
return ret;
|
||||
|
||||
if (charge > 0)
|
||||
value = charge;
|
||||
else if (discharge > 0)
|
||||
value = -1 * discharge;
|
||||
if (discharge > 0) {
|
||||
*cur = -1 * discharge;
|
||||
return 0;
|
||||
}
|
||||
|
||||
*cur = value;
|
||||
current_read_fail:
|
||||
return ret;
|
||||
return iio_read_channel_raw(info->iio_channel[BAT_CHRG_CURR], cur);
|
||||
}
|
||||
|
||||
static int fuel_gauge_get_vocv(struct axp288_fg_info *info, int *vocv)
|
||||
|
|
Loading…