clk: sunxi-ng: fix the A64/H5 clock description of DE2 CCU
The clocks of A64/H5 SoCs in the DE2 CCU is the same as the clocks in H3
DE2 CCU rather than the A83T DE2 CCU (the parent of them is the DE
module clock).
Fix this by change the clock descriptions to use the clocks of H3.
Fixes: 763c5bd045
("clk: sunxi-ng: add support for DE2 CCU")
Signed-off-by: Icenowy Zheng <icenowy@aosc.io>
Signed-off-by: Chen-Yu Tsai <wens@csie.org>
This commit is contained in:
parent
19368d9974
commit
cf4881c129
|
@ -177,10 +177,10 @@ static const struct sunxi_ccu_desc sun8i_h3_de2_clk_desc = {
|
|||
};
|
||||
|
||||
static const struct sunxi_ccu_desc sun50i_a64_de2_clk_desc = {
|
||||
.ccu_clks = sun8i_a83t_de2_clks,
|
||||
.num_ccu_clks = ARRAY_SIZE(sun8i_a83t_de2_clks),
|
||||
.ccu_clks = sun8i_h3_de2_clks,
|
||||
.num_ccu_clks = ARRAY_SIZE(sun8i_h3_de2_clks),
|
||||
|
||||
.hw_clks = &sun8i_a83t_de2_hw_clks,
|
||||
.hw_clks = &sun8i_h3_de2_hw_clks,
|
||||
|
||||
.resets = sun50i_a64_de2_resets,
|
||||
.num_resets = ARRAY_SIZE(sun50i_a64_de2_resets),
|
||||
|
|