bnx2: Fix bandwidth allocation for some MF modes
Management firmware tells driver in case bandwidth configuration for a specific function exists, but [regretably] the same field has different meanings depending on the multi-function mode - it can either be a percentile value or an actual speed. For newer multi-function modes current logic is incorrect - driver understands values as actual speeds instead of percentages, causing the resulting chip configuration to be incorrect. Signed-off-by: Yuval Mintz <Yuval.Mintz@qlogic.com> Signed-off-by: David S. Miller <davem@davemloft.net>