thermal: imx: Use better parameter names than "val"
The values passed to imx_init_calib() and imx_init_temp_grade() are read from specific OCOTP values. Use their names (in lower case) as parameter name instead of "val" to make the code easier to understand. Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
This commit is contained in:
parent
d790405d1b
commit
e4bb2240d4
|
@ -347,13 +347,13 @@ static struct thermal_zone_device_ops imx_tz_ops = {
|
|||
.set_trip_temp = imx_set_trip_temp,
|
||||
};
|
||||
|
||||
static int imx_init_calib(struct platform_device *pdev, u32 val)
|
||||
static int imx_init_calib(struct platform_device *pdev, u32 ocotp_ana1)
|
||||
{
|
||||
struct imx_thermal_data *data = platform_get_drvdata(pdev);
|
||||
int t1, n1;
|
||||
u64 temp64;
|
||||
|
||||
if (val == 0 || val == ~0) {
|
||||
if (ocotp_ana1 == 0 || ocotp_ana1 == ~0) {
|
||||
dev_err(&pdev->dev, "invalid sensor calibration data\n");
|
||||
return -EINVAL;
|
||||
}
|
||||
|
@ -364,7 +364,7 @@ static int imx_init_calib(struct platform_device *pdev, u32 val)
|
|||
* Use universal formula now and only need sensor value @ 25C
|
||||
* slope = 0.4297157 - (0.0015976 * 25C fuse)
|
||||
*/
|
||||
n1 = val >> 20;
|
||||
n1 = ocotp_ana1 >> 20;
|
||||
t1 = 25; /* t1 always 25C */
|
||||
|
||||
/*
|
||||
|
@ -392,12 +392,12 @@ static int imx_init_calib(struct platform_device *pdev, u32 val)
|
|||
return 0;
|
||||
}
|
||||
|
||||
static void imx_init_temp_grade(struct platform_device *pdev, u32 val)
|
||||
static void imx_init_temp_grade(struct platform_device *pdev, u32 ocotp_mem0)
|
||||
{
|
||||
struct imx_thermal_data *data = platform_get_drvdata(pdev);
|
||||
|
||||
/* The maximum die temp is specified by the Temperature Grade */
|
||||
switch ((val >> 6) & 0x3) {
|
||||
switch ((ocotp_mem0 >> 6) & 0x3) {
|
||||
case 0: /* Commercial (0 to 95C) */
|
||||
data->temp_grade = "Commercial";
|
||||
data->temp_max = 95000;
|
||||
|
|
Loading…