mtd: nand: sunxi: let the NAND controller control the CE line

We don't need to manually toggle the CE line since the controller handles
it for us. Moreover, keeping the CE line low when interacting with a DDR
NAND can be problematic (data loss in some corner cases).

Signed-off-by: Boris Brezillon <boris.brezillon@free-electrons.com>
This commit is contained in:
Boris Brezillon 2016-03-04 17:21:35 +01:00
parent e9aa671f69
commit ece03cfd52
1 changed files with 0 additions and 10 deletions

View File

@ -514,21 +514,11 @@ static void sunxi_nfc_cmd_ctrl(struct mtd_info *mtd, int dat,
struct sunxi_nand_chip *sunxi_nand = to_sunxi_nand(nand);
struct sunxi_nfc *nfc = to_sunxi_nfc(sunxi_nand->nand.controller);
int ret;
u32 tmp;
ret = sunxi_nfc_wait_cmd_fifo_empty(nfc);
if (ret)
return;
if (ctrl & NAND_CTRL_CHANGE) {
tmp = readl(nfc->regs + NFC_REG_CTL);
if (ctrl & NAND_NCE)
tmp |= NFC_CE_CTL;
else
tmp &= ~NFC_CE_CTL;
writel(tmp, nfc->regs + NFC_REG_CTL);
}
if (dat == NAND_CMD_NONE && (ctrl & NAND_NCE) &&
!(ctrl & (NAND_CLE | NAND_ALE))) {
u32 cmd = 0;