clk: ti: fix building without legacy omap3

When CONFIG_ATAGS or CONFIG_OMAP3 is disabled, we get a build error:

In file included from include/linux/clk-provider.h:15:0,
                 from drivers/clk/ti/clk.c:19:
drivers/clk/ti/clk.c: In function 'ti_clk_add_aliases':
drivers/clk/ti/clk.c:438:29: error: 'simple_clk_match_table' undeclared (first use in this function); did you mean 'simple_attr_write'?

Moving the match table down fixes it.

Fixes: c17435c56b ("clk: ti: add API for creating aliases automatically for simple clock types")
Signed-off-by: Arnd Bergmann <arnd@arndb.de>
Acked-by: Tero Kristo <t-kristo@ti.com>
Signed-off-by: Stephen Boyd <sboyd@codeaurora.org>
This commit is contained in:
Arnd Bergmann 2017-04-19 19:44:56 +02:00 committed by Stephen Boyd
parent 2158a09395
commit fc04f27dfc
1 changed files with 6 additions and 6 deletions

View File

@ -371,12 +371,6 @@ struct clk __init *ti_clk_register_clk(struct ti_clk *setup)
return clk;
}
static const struct of_device_id simple_clk_match_table[] __initconst = {
{ .compatible = "fixed-clock" },
{ .compatible = "fixed-factor-clock" },
{ }
};
int __init ti_clk_register_legacy_clks(struct ti_clk_alias *clks)
{
struct clk *clk;
@ -425,6 +419,12 @@ int __init ti_clk_register_legacy_clks(struct ti_clk_alias *clks)
}
#endif
static const struct of_device_id simple_clk_match_table[] __initconst = {
{ .compatible = "fixed-clock" },
{ .compatible = "fixed-factor-clock" },
{ }
};
/**
* ti_clk_add_aliases - setup clock aliases
*