The function signature for spin_event_timeout() has changed in version V9.
Adjust the mpc5200 AC97 driver to use the new function.
Signed-off-by: Jon Smirl <jonsmirl@gmail.com>
Acked-by: Timur Tabi <timur@freescale.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
I've implemented retries for when the AC97 hardware doesn't reset on
first try. About 10% of the time both the Efika and pcm030 AC97 codecs
don't reset on first try and need to be poked multiple times. Failure
is indicated by not having the link clock start ticking. Every once in
a while even five pokes won't get the link started and I have to power
cycle.
Signed-off-by: Jon Smirl <jonsmirl@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>