Today the battery recharge is determined with a voltage threshold. This
voltage threshold is only valid when the battery is relaxed. In charging
algorithm the voltage read is the loaded battery voltage and no
compensation is done to get the relaxed voltage. When maintenance
charging is not selected, this makes the recharging condition to almost
immediately activate when there is a discharge present on the battery.
Depending on which vendor the battery comes from this behavior can wear
out the battery much faster than normal.
The fuelgauge driver is responsible to monitor the actual battery
capacity and is able to estimate the remaining capacity. It is better to
use the remaining capacity as a limit to determine when battery should
be recharged.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Marcus Cooper <marcus.xm.cooper@stericsson.com>
Reviewed-by: Hakan BERG <hakan.berg@stericsson.com>
Reviewed-by: Jonas ABERG <jonas.aberg@stericsson.com>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
Let's rename the Device Tree node which contains information about
an attached battery to something more easily readable.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Currently the AB8500 battery management subsystem receives platform
specific information via two different means depending on how the
platform is booted. If DT is not enabled, a reference to a *_bm_data
data structure containing each platform specific attribute is passed
though platform_data. However, if DT is enabled, then platform_data
is empty and the reference is gained though a DT specific probe
function. There are two issues here 1) the same reference is
being collected each time and 2) the DT way doesn't allow any
provisions to select different platform specific attributes, which
kind of defeats the object.
Cc: Samuel Ortiz <sameo@linux.intel.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
The platform specific battery management configuration data structure
is currently called 'bat' short for 'battery'; however, it contains
information for all components of the battery management group, rather
than information pertaining to the battery itself - there are other
structures for that. So, in keeping with its structure namesake
'abx500_bm_data', we rename it to 'bm' here. Using similar logic,
we're also renaming 'bmdevs_of_probe' to the more device specific
'ab8500_bm_of_probe'.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
We can actually write bmdevs_of_probe to be easier to follow, use
less lines of code and we can even render a variable unused so
that we can remove it completely.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Simple patch to rectify incorrect tabbing. Also adds some
coding style clean-ups to make it easier to read.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
property, battery-type shall be one of supported technology type
instead blank
- refer: Documentation/devicetree/bindings/power_supply/ab8500/fg.txt
for the list supported types
- this patch appends to ab8500 bm devs DT binding patch set
ref: commit-id e0f1abeba5
git://git.infradead.org/battery-2.6.git
- promote ab8500_fg probe to happen before ab8500_btemp probe as
btemp driver depends on fuelgauge list,
ref: ab8500_fg_get(...)
Signed-off-by: Rajanikanth H.V <rajanikanth.hv@stericsson.com>
This patch adds device tree support for battery-temperature-monitor driver
Signed-off-by: Rajanikanth H.V <rajanikanth.hv@stericsson.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
- This patch adds device tree support for fuelgauge driver
- optimize bm devices platform_data usage and of_probe(...)
Note: of_probe() routine for battery managed devices is made
common across all bm drivers.
- test status:
- interrupt numbers assigned differs between legacy and FDT mode.
Signed-off-by: Rajanikanth H.V <rajanikanth.hv@stericsson.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>