Reported-by: Alex Lyakas <alexl@mellanox.co.il>
Signed-off-by: Vasu Dev <vasu.dev@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Adds missing exch release when RRQ is accepted by calling
fc_seq_ls_acc. Adds common exch release for fc_exch_els_rrq
by use of out label.
Reported-by: Alex Lyakas <alexl@mellanox.co.il>
Signed-off-by: Vasu Dev <vasu.dev@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Initializing these libfc globals per lport could mess up exch
allocation/free for existing lport.
So this patch moves their initialization to fc_setup_exch_mgr
so that these globals gets initialized only once for libfc.
Reported-by: Alex Lyakas <alexl@mellanox.co.il>
Signed-off-by: Vasu Dev <vasu.dev@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
It's possible and harmless to get FLOGI timeouts
while in RESET state. Don't do a WARN_ON in that case.
Also, split out the other WARN_ONs in fc_lport_timeout, so
we can tell which one is hit by its line number.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Fix minor errors.
A debug message said an RLIR was received instead of ECHO.
"Expected" was misspelled in several places.
Fix a type cast from u32 to __be32.
Rob, Some of these may have been also taken care of in your
other doc cleanup patch. Feel free to fold them in.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This bug is exposed when there is a link flap in LLD. Particularly, when it
happens right after a SCSI write command is sent out, no FCP_DATA is sent,
causing fsp->status_code to be set as FC_DATA_UNDRUN in fc_fcp_complete_locked
even no SCSI status is received. Consequently, fc_io_compl treats this as DID_OK.
This results in SCSI returning successful to the initial I/O request even
there is no DATA actually sent. Particularly, if you run an I/O tool w/ data
verification on, the read back for verification is gonna fail.
This is fixed here by checking when FC_DATA_UNDRUN happens, SCSI status is
received w/ FC_SRB_RCV_STATUS set in fsp->state.
Signed-off-by: Yi Zou <yi.zou@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This argument isn't used, let's not pass it into the routine.
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
These are a few functions that were not used by other
modules. They did not need to be exported so this patch
removes the EXPORT_SYMBOLS call for each.
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
xid 0 was used as an indication of invalid xid before but now xid 0
can be used as a valid exchange i. This patch fixes the ddp completion
in fcp layer, i.e., in fc_fcp.c:fc_fcp_ddp_done() function, to make sure it
does not use xid 0 for indication of an invalid xid, instead, it now
uses use FC_XID_UNKNOWN for such indication.
Signed-off-by: Yi Zou <yi.zou@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
A received Fibre Channel ELS PRLI request contains a bit that
indicates whether the remote port supports certain retry processing
sequences. The test for this bit was somehow coded to use multiply
instead of AND!
This case would apply only for target mode operation, and it is
unlikely to be noticed as an initiator.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
I saw an lport debug message from the exchange manager saying:
"lport 70500: Received response for out of range oxid:ffff"
A trace showed this was a BA_RJT sent due to an incoming ABTS
which arrived on an unknown exchange. So, the sender of the
BA_RJT was in error, but in this case, both the initiator and
responder were the same machine.
The OX_ID and RX_ID should not have been reversed in this case.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When an RSCN indicates changes to individual remote ports,
don't blindly log them out and then back in. Instead, determine
whether they're still in the directory, by doing GPN_ID.
If that is successful, call login, which will send ADISC and reverify,
otherwise, call logoff. Perhaps we should just delete the rport,
not send LOGO, but it seems safer.
Also, fix a possible issue where if a mix of records in the RSCN
cause us to queue disc_ports for disc_single and then we decide
to do full rediscovery, we leak memory for those disc_ports queued.
So, go through the list of disc_ports even if doing full discovery.
Free the disc_ports in any case. If any of the disc_single() calls
return error, do a full discovery.
The ability to fill in GPN_ID requests was added to fc_ct_fill().
For this, it needs the FC_ID to be passed in as an arg.
The did parameter for fc_elsct_send() is used for that, since the
actual D_DID will always be 0xfffffc for all CT requests so far.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The local port facility has been replying to ADISC requests without
looking to see if the remote port is logged in. This is incorrect.
An ADISC request requires PLOGI first. It should be rejected if
the sending remote port is not logged in.
This is like other incoming requests that require login, all of
which should be handled in the remote port module.
Move the ADISC request handling from fc_lport.c to fc_rport.c.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When rport_login is called on an rport that is already thought
to be logged in, use ADISC. If that fails, redo PLOGI.
This is less disruptive after fabric changes that don't affect
the state of the target.
Implement the sending of ADISC via fc_els_fill.
Add ADISC state to the rport state machine. This is entered from READY
and returns to READY after successful completion. If it fails, the rport
is either logged off and deleted or re-does PLOGI.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
fc_rport_logo_resp() had a call to fc_rport_enter_rtv() if the
LOGO was accepted. This must've been a copy/paste mistake, but
it didn't matter since we don't stay in the LOGO state long enough
to hit this code.
Change fc_rport_logo_resp() to just enter the delete state
no matter what.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
After a quick link flap, a target was seen to send us a LOGO.
Apparently, it saw an RSCN reporting that we had dropped out of the
fabric after we had logged back into it.
This is likely in larger fabrics (more than 2 FC switches) after
a quick link flap at the initiator. Each link transition causes
an port-specific RSCN to the target. After the link comes back up,
the initiator successfully discovers and does a PLOGI to the target
before the target sees the first RSCN reporting the initiator is gone,
and it sends a LOGO. The target may see a subsequent RSCN saying the
port is back, but probably wouldn't send a PLOGI and leaves it
up to the initiator to re-login.
An RSCN can be delayed by the switches due to software layers but a
PLOGI is forwarded in hardware causing the PLOGI to beat the RSCN.
If a remote port is in the discovered set and sends a LOGO, re-login to it.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When receiving an ELS request, if the request isn't recognized,
the unsupported operation error should be given even if the port
is not found or not logged in.
Also, the LOGO request shouldn't give the login-required explanation.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
libfc receives PLOGIs from switches which are trying to discover what
kind of devices are present, and from other initiators to find out
if we're a target.
As an initiator, some argue we don't need to handle incoming PLOGI
requests, and we currently reject them from unknown remote ports,
but accept them is we're in the middle of a PLOGI to the remote port.
For eventual target implementations, we want to handle them always.
For incoming PLOGI, don't fail if the rport_priv doesn't exist.
Just create it and go become READY without going through PRLI. If
PRLI occurs, then our roles will be set and we'll become READY again.
Also, allow incoming PRLI in RTV state.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Improve lport and rport debug messages to indicate whether
the response is LS_ACC, LS_RJT, closed, or timeout.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The rport_lookup function must be called while holding the disc_mutex.
Otherwise, the rdata could be deleted just after that by another thread.
All callers now check the state after grabbing the rdata rp_mutex.
Even though rport_lookup skips ports in DELETE state, it does that
without holding the rdata rp_mutex, so that the state may change.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This moves the remote port lookup for incoming ELS requests into
fc_rport.c, in preparation for handing PLOGI and LOGO from
unknown rports.
This changes the arg to rport_recv_req from an rdata to an lport.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Don't trust previous roles, reset them when we receive a PRLI.
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Currently these values are initialized by the callers. This was exposed
by a later patch that adds PLOGI request support. The patch failed to
initialize the new remote port's roles and it caused problems. This patch
has the rport_create routine initialize the identifiers and then the
callers can override them with real values.
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
It's possible to "restart" discovery before it was started if
an RSCN is received early enough. We were jumping to 0
due to the disc_callback function pointer not getting set.
Don't restart discovery if disc_callback is NULL.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The discovery code had a special-case for the point-to-point mode,
which used a bunch of code that wasn't really needed.
Now that rport_create adds the rport to the discovery list,
completely skip discovery for the point-to-point case.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
In fc_disc_gpn_ft_parse(), after fc_disc_done() is called, the
disc state is changed by setting buf_len = 0. This is wrong
since the discovery may have restarted. Instead, return
after calling fc_disc_done.
Also, return an error on memory allocation failure.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Currently fc_disc_timeout() restarts discovery only if it is not pending.
When the timer is scheduled, the discovery is left pending, so the
timeout never restarts it.
Fix by not checking for pending in the timeout handler.
If discovery is stopped and restarted in the meantime, the timeout will
be canceled.
Also, when a new discovery is started, the retry count wasn't cleared.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
On some switches, an empty zone causes GPN_FT to be rejected
with reason 9 (unable) explanation 7 (FC-4 types not registered),
which causes discovery to be retried endlessly. Treat this as
just an empty response and consider discovery complete.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Abhijeet Joglekar wrote: "In gpn_ft_resp, if the payload is short,
or unexpected response or out of sequence frame, then we just
return and do nothing. We should either enter fc_disc_done()
with DISC_EV_FAIL which will then restart any queued discovery
requests or call lport module which will reset local port,
or we should call fc_disc_error() so that the gpn_ft is retried.
The situation as is causes discovery to remain pending and never
get restarted, in these rare cases. We saw this due to a coding
bug in fc_disc before. The only ways it could happen would be
bugs, packet corruption or an FC fabric problem.
Change it to fail discovery. The local port will restart
discovery, although it probably should just give up until
the next link flap.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Code cleanup for fc_disc_gpn_ft_resp().
Some of the fc_disc.c code was poorly formatted. For example, some lines
in fc_disc.c were unnecessarily truncated and the buf variable could
be eliminated.
Also moved the increment of seq_count into fc_disc_gpn_ft_parse(), to
avoid doing it separately before each call.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When an RSCN is received during fabric discovery, it restarts.
After the restart, disc->seq_count was incremented, so when
the first frame was received, it was considered "out of sequence".
That left the state disc->active, preventing further discoveries.
Change to advance the sequence count before parsing, so that it
won't be changed after a potential restart.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When receiving an RSCN, do not log off all rports. This is
extremely disruptive. If, after the GPN_FT response, some
rports haven't been listed, delete them.
Add field disc_id to structs fc_rport_priv and fc_disc.
disc_id is an arbitrary serial number used to identify the
rports found by the latest discovery. This eliminates the need
to go through the rport list when restarting discovery.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Move the libfc remote port lookup function into fc_rport.c.
This seems like the best place for it.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Since the rport list maintenance is now done in the rport module,
the callback (and ops) are usually not necessary.
Allow rdata->ops to be left NULL if nothing needs
to be done in an event callback.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
For future discovery patches, change rport_create to return a previously
created rport_priv that has the FC_ID as long as it isn't in deleted state.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The list of remote ports (struct fc_rport_priv) has been
maintained by the discovery module. In preparation for having
lport->tt.rport_create() do a lookup first, maintain the
rports list in the rport module. It will still be protected
by the disc_mutex.
The DNS rport is an exception for until after further patches.
For now, do not add it to the list.
The point-to-point rport will be in the discovery list.
So at shutdown, it doesn't need to be separately logged out.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The lport rport callback can only be called for the dNS rport,
since its the only rport who's ops point to that function.
Remove unnecessary checking and debug messages.
Put the locking outside the switch statement as a simplification.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Don't print large negative decimal numbers for frame pointers in
the debug messages from fc_rport_error(). Just print 0 if its a
frame pointer, and print the error numbers as positive.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Delete unused disc->delay element.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
There was no need to have the discovery status stored in struct fc_disc.
Change fc_disc_done() to take the discovery status as an argument
and just pass it on to the discovery callback.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When a remote port becomes ready and a LOGO is received before
the READY event is in rport_work waiting on the mutex, the
event is changed to LOGO and the work queued, so both the
calls to rport_work see the LOGO event, and both try to do
the list_del(), causing a crash.
Don't change the event if it is already set.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Don't create a "dummy" remote port to go with fc_rport_priv.
Make the rport truly optional by allocating fc_rport_priv separately
and not requiring a dummy rport to be there if we haven't yet done
fc_remote_port_add().
The fc_rport_libfc_priv remains as a structure attached to the
rport for I/O purposes.
Be sure to hold references on rdata when the lock is dropped in
fc_rport_work().
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Remote ports will become READY more than once after
ADISC is implemented in a later patch.
The event callback that has been called "CREATED" will mean "READY".
Rename it now in preparation for those changes.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This is a cleanup without semantic changes to use a switch
statement instead of a series of if-statements in fc_rport_work(),
and to move some declarations up to the top.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Allow a struct fc_rport_priv to have no fc_rport associated with it.
This sets up to remove the need for "rogue" rports.
Add a few fields to fc_rport_priv that are needed before the fc_rport
is created. These are the ids, maxframe_size, classes, and rport pointer.
Remove the macro PRIV_TO_RPORT(). Just use rdata->rport where appropriate.
To take the place of the get_device()/put_device ops that were used to
hold both the rport and rdata, add a reference count to rdata structures
using kref. When kref_get decrements the refcount to zero, a new template
function releasing the rdata should be called. This will take care of
freeing the rdata and releasing the hold on the rport (for now). After
subsequent patches make the rport truly optional, this release function
will simply free the rdata.
Remove the simple inline function fc_rport_set_name(), which becomes
semanticly ambiguous otherwise. The caller will set the port_name and
node_name in the rdata->Ids, which will later be copied to the rport
when it its created.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
tt.elsct_send is used by both FCP and by the rport state machine.
After further patches, these two modules will use different
structures for the remote port.
So, change elsct_send to use the FC_ID instead of the fc_rport_priv
as its argument. It currently only uses the FC_ID anyway.
For CT requests the destination FC_ID is still implicitly 0xfffffc.
After further patches the did arg on CT requests will be used to
specify the FC_ID being inquired about for GPN_ID or other queries.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The rport and discovery modules deal with remote ports
before fc_remote_port_add() can be done, because the
full set of rport identifiers is not known at early stages.
In preparation for splitting the fc_rport/fc_rport_priv allocation,
make fc_rport_priv the primary interface for the remote port and
discovery engines.
The FCP / SCSI layers still deal with fc_rport and
fc_rport_libfc_priv, however.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The interface for lport->tt.rport_create() takes a fc_disc_port arg,
which is unnatural for most calls. The only reason for this was
to avoid passing in the local port as an argument, but otherwise
added to complexity.
Simplify by just using lport and fc_rport_identifiers.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
While the I/O and LLD interfaces use fc_rport_libfc_priv, the
disc and rport interfaces will use fc_rport_priv, which will
be separately allocated.
Change the disc and rport usage of fc_rport_libfc_priv to fc_rport_priv.
Use #define temporarily to make both names equivalent until a
subsequent patch splits them.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
1. Updates fcoe_rcv() to queue incoming frames to the fcoe per
cpu thread on which this frame's exch was originated and simply
use current cpu for request exch not originated by initiator.
It is redundant to add this code under CONFIG_SMP, so removes
CONFIG_SMP uses around this code.
2. Updates fc_exch_em_alloc, fc_exch_delete, fc_exch_find to use
per cpu exch pools, here fc_exch_delete is rename of older
fc_exch_mgr_delete_ep since ep/exch are now deleted in pools
of EM and so brief new name is sufficient and better name.
Updates these functions to map exch id to their index into exch
pool using fc_cpu_mask, fc_cpu_order and EM min_xid.
This mapping is as per detailed explanation about this in
last patch and basically this is just as lower fc_cpu_mask
bits of exch id as cpu number and upper bit sum of EM min_xid
and exch index in pool.
Uses pool next_index to keep track of exch allocation from
pool along with pool_max_index as upper bound of exches array
in pool.
3. Adds exch pool ptr to fc_exch to free exch to its pool in
fc_exch_delete.
4. Updates fc_exch_mgr_reset to reset all exch pools of an EM,
this required adding fc_exch_pool_reset func to reset exches
in pool and then have fc_exch_mgr_reset call fc_exch_pool_reset
for each pool within each EM for a lport.
5. Removes no longer needed exches array, em_lock, next_xid, and
total_exches from struct fc_exch_mgr, these are not needed after
use of per cpu exch pool, also removes not used max_read,
last_read from struct fc_exch_mgr.
6. Updates locking notes for exch pool lock with fc_exch lock and
uses pool lock in exch allocation, lookup and reset.
Signed-off-by: Vasu Dev <vasu.dev@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>