Since commit e446630c96, i.e. v2.6.35-rc1,
the mcp251x chip model can be selected via the modalias member in the
struct spi_board_info. The driver stores the actual model in the
struct mcp251x_platform_data.
From the driver point of view the platform_data should be read only.
Since all in-tree users of the mcp251x have already been converted to
the modalias method, this patch moves the "model" member from the
struct mcp251x_platform_data to the driver's private data structure.
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
Cc: Christian Pellegrin <chripell@fsfe.org>
Cc: Marc Zyngier <maz@misterjones.org>
This core is found on some Freescale SoCs and also some Coldfire
SoCs. Support for Coldfire is missing though at the moment as
they have an older revision of the core which does not have RX FIFO
support.
Signed-off-by: Sascha Hauer <s.hauer@pengutronix.de>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
Acked-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
The member "clock" of struct "sja1000_platform_data" is documented as
"CAN bus oscillator frequency in Hz" but it's actually used as the CAN
clock frequency, which is half of it. To avoid further confusion, this
patch fixes it by renaming the member to "osc_freq". That way, also
non mainline users will notice the change. The platform code for the
relevant boards is updated accordingly. Furthermore, pre-defined
values are now used for the members "ocr" and "cdr".
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Acked-by: Marc Kleine-Budde <mkl@pengutronix.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
Chip model can now be selected directly by matching the modalias name
(instead of filling the .model field in platform_data), and allows the
module to be auto-loaded. Previous behaviour is of course still supported.
Convert the two in-tree users to this feature (icontrol & zeus).
Tested on an Zeus platform (mcp2515).
Signed-off-by: Marc Zyngier <maz@misterjones.org>
Acked-by: Christian Pellegrin <chripell@fsfe.org>
Cc: Edwin Peer <epeer@tmtservices.co.za>
Acked-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
CAN module on AM3517 requires programming of IO expander as part
of init sequence - to enable CAN PHY. Added platform specific
callback to handle phy control(switch on /off).
Signed-off-by: Sriramakrishnan <srk@ti.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Signed-off-by: Christian Pellegrin <chripell@fsfe.org>
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
TI HECC (High End CAN Controller) module is found on many TI devices. It
has 32 hardware mailboxes with full implementation of CAN protocol 2.0B
with bus speeds up to 1Mbps. Specifications of the module are available
on TI web <http://www.ti.com>
Signed-off-by: Anant Gole <anantgole@ti.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This patch adds a generic driver for SJA1000 chips on the OpenFirmware
platform bus found on embedded PowerPC systems. You need a SJA1000 node
definition in your flattened device tree source (DTS) file similar to:
can@3,100 {
compatible = "nxp,sja1000";
reg = <3 0x100 0x80>;
interrupts = <2 0>;
interrupt-parent = <&mpic>;
nxp,external-clock-frequency = <16000000>;
};
See also Documentation/powerpc/dts-bindings/can/sja1000.txt.
CC: devicetree-discuss@ozlabs.org
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This driver adds support for the SJA1000 chips connected to the
"platform bus", which can be found on various embedded systems.
Signed-off-by: Sascha Hauer <s.hauer@pengutronix.de>
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
Signed-off-by: Oliver Hartkopp <oliver.hartkopp@volkswagen.de>
Signed-off-by: David S. Miller <davem@davemloft.net>