Bug: Unable to send and receive Ethernet packets with Micrel PHY.
Affected devices:
KSZ8031RNL (commercial temp)
KSZ8031RNLI (industrial temp)
Description:
PHY device is correctly detected during probe.
PHY power-up default is 25MHz crystal clock input
and output 50MHz RMII clock to MAC.
Reconfiguration of PHY to input 50MHz RMII clock from MAC
causes PHY to become unresponsive if clock source is changed
after Operation Mode Strap Override (OMSO) register setup.
Cause:
Long lead times on parts where clock setup match circuit design
forces the usage of similar parts with wrong default setup.
Solution:
Swapped KSZ8031 register setup and added phy_write return code validation.
Tested with Freescale i.MX28 Fast Ethernet Controler (fec).
Signed-off-by: Bruno Thomsen <bth@kamstrup.dk>
Signed-off-by: David S. Miller <davem@davemloft.net>
The KSZ8021 and KSZ8031 support RMII reference input clocks of 25MHz
and 50MHz. Both PHYs differ in the default frequency they expect
after reset. If this differs from the actual input clock, then
register 0x1f bit 7 must be changed.
Signed-off-by: Sascha Hauer <s.hauer@pengutronix.de>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The KSZ9031 appears to suffer from the same hardware bug as described
for the KSZ9021 in commit 32fcafbcd1
("net/phy: micrel: Disable asymmetric pause for KSZ9021")
you have to unplug the cable and plug it back to get it to work.
Remove the SUPPORTED_Asym_Pause flag for the KSZ9031 to fix this.
Signed-off-by: Mike Looijmans <mike.looijmans@topic.nl>
Signed-off-by: David S. Miller <davem@davemloft.net>
The Micrel ksz9021 PHY does not support standard IEEE standard MMD
extended register access, therefore requires stubs to fail the read
register method and do nothing for the write register method when
libphy attempts to read and/or configure Energy Efficient Ethernet
features in PHYS that do support those features. This problem
was observed on an Altera Cyclone V SOC development kit that
uses the Synopsys EMAC and the Micrel ksz9021 PHY. This patch
was tested on the same board, and Energy Efficient Ethernet is
now disabled as expected since the Micrel PHY does not support that
feature.
Signed-off-by: Vince Bridgers <vbridgers2013@gmail.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Adds support for ksz9031 PAD skew configuration over devicetree.
Signed-off-by: Hubert Chaumette <hchaumette@adeneo-embedded.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
In ksz9021_load_values_from_of() val2 to val4 aren't tested against their
initialization value.
This causes the test to always succeed, and this value to be used as if it
was loaded from the devicetree instead of being ignored, in case of a
missing/invalid property in the ethernet OF device node.
As a result, the value "0" is written to the relevant registers.
Change the conditions to test against the right initialization value.
Signed-off-by: Hubert Chaumette <hchaumette@adeneo-embedded.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Commit 20d8435a1c (phy: micrel: add of configuration for LED mode) made the
obvious mistake when masking off the LED mode bits: forgot to do a logical NOT
to the mask with which it ANDs the register value, so that unrelated bits are
cleared instead.
Signed-off-by: Sergei Shtylyov <sergei.shtylyov@cogentembedded.com>
Acked-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com>
Acked-by: Ben Dooks <ben.dooks@codethink.co.uk>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Add support for the led-mode property for the following PHYs
which have a single LED mode configuration value.
KSZ8001 and KSZ8041 which both use register 0x1e bits 15,14 and
KSZ8021, KSZ8031 and KSZ8051 which use register 0x1f bits 5,4
to control the LED configuration.
Signed-off-by: Ben Dooks <ben.dooks@codethink.co.uk>
Signed-off-by: David S. Miller <davem@davemloft.net>
Conflicts:
drivers/net/ethernet/intel/i40e/i40e_main.c
drivers/net/macvtap.c
Both minor merge hassles, simple overlapping changes.
Signed-off-by: David S. Miller <davem@davemloft.net>
checkpatch spotted a few spaces vs tabs errors, fix them.
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Renesas R-Car development boards use KSZ8041RNLI PHY which for some reason has
ID of 0x00221537 that is not documented for KSZ8041-family PHYs and does not
match the documented ID of 0x0022151x (where 'x' is the revision). We have
to add the new #define PHY_ID_* and new ksphy_driver[] entry, almost the same
as KSZ8041 one, differing only in the 'phy_id' and 'name' fields.
Signed-off-by: Sergei Shtylyov <sergei.shtylyov@cogentembedded.com>
Tested-by: Geert Uytterhoeven <geert@linux-m68k.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
All supported Micrel PHYs implement the standard "power down" bit 11 of BMCR,
so this patch adds support using the generic genphy_{suspend,resume} functions.
Signed-off-by: Patrice Vilchez <patrice.vilchez@atmel.com>
[b.brezillon@overkiz.com: adapt to newer kernel and generalize to other phys]
Signed-off-by: Boris BREZILLON <b.brezillon@overkiz.com>
[nicolas.ferre@atmel.com: commit message modification]
Signed-off-by: Nicolas Ferre <nicolas.ferre@atmel.com>
Cc: David J. Choi <david.choi@micrel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Some boards require custom PHY configuration, for example due to trace
length differences. Add the ability to configure these registers in
order to get the PHY to function on boards that need it.
Because PHYs are auto-detected based on MDIO device IDs, allow PHY
configuration to be specified in the parent Ethernet device node if no
PHY device node is present.
Signed-off-by: Sean Cross <xobs@kosagi.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
ksz8873mll_read_status() is used only in this file.
Fix the following sparse warning:
drivers/net/phy/micrel.c:147:5: warning: symbol 'ksz8873mll_read_status' was not declared. Should it be static?
Signed-off-by: Jingoo Han <jg1.han@samsung.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The flag MICREL_PHY_50MHZ_CLK is not of exclusive use of KSZ8051
model. At least KSZ8021 and KSZ8031 models also use it.
This patch moves the handling of this and future flags to a
separate function so that the different PHY models can call it on
their init function, if needed.
Signed-off-by: Hector Palacios <hector.palacios@digi.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Micrel PHY KSZ8031 is similar to KSZ8021 and also requires the special
initialization of "Operation Mode Strap Override" in reg 0x16
introduced in 212ea99 (phy/micrel: Implement support for KSZ8021).
Signed-off-by: Hector Palacios <hector.palacios@digi.com>
Reviewed-by: Marek Vasut <marex@denx.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
Phyter KSZ9021 has hardware bug. If asymmetric pause is enabled,
then it is necessary to disconnect and then reconnect the ethernet
cable to get the phyter working. The solution is to disable the
asymmetric pause.
Signed-off-by: Vlastimil Kosar <ikosar@fit.vutbr.cz>
Signed-off-by: David S. Miller <davem@davemloft.net>
Summary of changes:
.Newly added phys
-KSZ8081/KSZ8091, which has some phy ids.
-KSZ8061
-KSZ9031, which is Gigabit phy.
-KSZ886X, which has a switch function.
-KSZ8031, which has a same phy ids with KSZ8021.
Signed-off-by: David J. Choi <david.choi@micrel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
this will allow to detect the link between the switch and the soc
Signed-off-by: Jean-Christophe PLAGNIOL-VILLARD <plagnioj@jcrosoft.com>
Cc: netdev@vger.kernel.org
Signed-off-by: David S. Miller <davem@davemloft.net>
There is no such part as KS8001, KS8041 or KS8051. There are only
KSZ8001, KSZ8041 and KSZ8051. Rename these parts as such to match
the Micrel naming.
Signed-off-by: Marek Vasut <marex@denx.de>
Cc: David J. Choi <david.choi@micrel.com>
Cc: David S. Miller <davem@davemloft.net>
Cc: Nobuhiro Iwamatsu <nobuhiro.iwamatsu.yj@renesas.com>
Cc: Linux ARM kernel <linux-arm-kernel@lists.infradead.org>
Cc: Fabio Estevam <fabio.estevam@freescale.com>
Cc: Shawn Guo <shawn.guo@linaro.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
The KSZ8021 PHY was previously caught by KS8051, which is not correct.
This PHY needs additional setup if it is strapped for address 0. In such
case an reserved bit must be written in the 0x16, "Operation Mode Strap
Override" register. According to the KS8051 datasheet, that bit means
"PHY Address 0 in non-broadcast" and it indeed behaves as such on KSZ8021.
The issue where the ethernet controller (Freescale FEC) did not communicate
with network is fixed by writing this bit as 1.
Signed-off-by: Marek Vasut <marex@denx.de>
Cc: David J. Choi <david.choi@micrel.com>
Cc: David S. Miller <davem@davemloft.net>
Cc: Nobuhiro Iwamatsu <nobuhiro.iwamatsu.yj@renesas.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
If registering of one of them fails, all already registered drivers
of this module will be unregistered.
Use the new register/unregister functions in all drivers
registering more than one driver.
amd.c, realtek.c: Simplify: directly return registration result.
Tested with broadcom.c
All others compile-tested.
Signed-off-by: Christian Hohnstaedt <chohnstaedt@innominate.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
On a freescale imx6q platform, a hardware phy chip KSZ9021 is
recognized as a KS8001 chip by the current driver like this:
eth0: Freescale FEC PHY driver [Micrel KS8001 or KS8721]
KSZ9021 has phy_id 0x00221610, while KSZ8001 has phy_id
0x0022161a, the current phy_id_mask (0x00fffff0/0x00ffff10) can't
distinguish them. So change phy_id_mask to resolve this problem.
Although the micrel datasheet says that the 4 LSB of phyid2 register
contains the chip revision number and the current driver is designed
to follow this rule, in reality the chip implementation doesn't follow
it.
Cc: David J. Choi <david.choi@micrel.com>
Cc: David S. Miller <davem@davemloft.net>
Cc: Nobuhiro Iwamatsu <nobuhiro.iwamatsu.yj@renesas.com>
Signed-off-by: Hui Wang <jason77.wang@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Platform code can now set the MICREL_PHY_50MHZ_CLK bit of dev_flags in a fixup
routine (registered with phy_register_fixup_for_uid()), to make the KZS8051RNL
PHY work with 50MHz RMII reference clock.
Cc: David J. Choi <david.choi@micrel.com>
Signed-off-by: Baruch Siach <baruch@tkos.co.il>
Signed-off-by: David S. Miller <davem@davemloft.net>
MODULE_DEVICE_TABLE only expands to something if it's compiled
for a module. So when building-in support for the phys, the
mdio_device_id tables are unused. Marking them with __maybe_unused
fixes the following warnings:
drivers/net/phy/bcm63xx.c:134: warning: 'bcm63xx_tbl' defined but not used
drivers/net/phy/broadcom.c:933: warning: 'broadcom_tbl' defined but not used
drivers/net/phy/cicada.c:162: warning: 'cicada_tbl' defined but not used
drivers/net/phy/davicom.c:222: warning: 'davicom_tbl' defined but not used
drivers/net/phy/et1011c.c:114: warning: 'et1011c_tbl' defined but not used
drivers/net/phy/icplus.c:137: warning: 'icplus_tbl' defined but not used
drivers/net/phy/lxt.c:226: warning: 'lxt_tbl' defined but not used
drivers/net/phy/marvell.c:724: warning: 'marvell_tbl' defined but not used
drivers/net/phy/micrel.c:234: warning: 'micrel_tbl' defined but not used
drivers/net/phy/national.c:154: warning: 'ns_tbl' defined but not used
drivers/net/phy/qsemi.c:141: warning: 'qs6612_tbl' defined but not used
drivers/net/phy/realtek.c:82: warning: 'realtek_tbl' defined but not used
drivers/net/phy/smsc.c:257: warning: 'smsc_tbl' defined but not used
drivers/net/phy/ste10Xp.c:135: warning: 'ste10Xp_tbl' defined but not used
drivers/net/phy/vitesse.c:195: warning: 'vitesse_tbl' defined but not used
Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
Hello all:
This patch fixes what Ben mentioned, namely duplicated ids.
From: David J. Choi <david.choi@micrel.com>
Body of the explanation: This patch has changes as followings;
-support the interrupt from phy devices from Micrel Inc.
-support more phy devices, ks8737, ks8721, ks8041, ks8051 from Micrel.
-remove vsc8201 because this device was used only internal test at Micrel.
Signed-off-by: David J. Choi <david.choi@micrel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Missing name string in ks8001_driver, so we crash on register.
Reported-by: Ingo Molnar <mingo@elte.hu>
Tested-by: Ingo Molnar <mingo@elte.hu>
Signed-off-by: David S. Miller <davem@davemloft.net>
This is the first version of phy driver from Micrel Inc.
Signed-off-by: David J. Choi <david.choi@micrel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>