Add missing 'const' attribute to avoid the following compile warnings:
drivers/s390/net/ctcm_main.c: In function 'ctcm_init':
drivers/s390/net/ctcm_main.c:1864: warning: assignment from incompatible pointer type
drivers/s390/net/lcs.c: In function 'lcs_init_module':
drivers/s390/net/lcs.c:2468: warning: assignment from incompatible pointer type
drivers/s390/net/claw.c: In function 'claw_init':
drivers/s390/net/claw.c:3408: warning: assignment from incompatible pointer type
Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Technically there is no need to set the card offline to change
RX checksumming. Get rid of this stupid limitation.
Signed-off-by: Frank Blaschka <frank.blaschka@de.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The maximum TSO size OSA can handle is 15 * PAGE_SIZE. This
patch reduces gso_max_size to this value and adds some sanity
checks and statistics to the TSO implementation.
Since only layer 3 is able to do TSO move all TSO related functions
to the qeth_l3 module.
Signed-off-by: Frank Blaschka <frank.blaschka@de.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Setting a qeth device online requires to call function
ccw_device_set_online() for read-, write-, and data-subchannel.
Failures should be detected immediately without an attempt to
invoke follow-on activity qeth_qdio_clear_card().,
In addition, ccw_device_set_online calls are consolidated in
qeth_core_main.c only.
Signed-off-by: Ursula Braun <ursula.braun@de.ibm.com>
Signed-off-by: Frank Blaschka <frank.blaschka@de.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
EDDP code has been removed from qeth in 2009. This patch removes two
useless remaining EDDP-references.
Signed-off-by: Ursula Braun <ursula.braun@de.ibm.com>
Signed-off-by: Frank Blaschka <frank.blaschka@de.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Isolate data connection to a shared OSA card against other data
connections to the same OSA card. Connectivity between isolated
data connections sharing the same OSA card is therefore possible only
through external network gear (e.g. a router).
Signed-off-by: Einar Lueck <elelueck@de.ibm.com>
Signed-off-by: Frank Blaschka <frank.blaschka@de.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
tx_bytes value must be updated by skb length before skb is freed.
Signed-off-by: Ursula Braun <ursula.braun@de.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The cu3088-driver used as common base for lcs- and ctcm-devices
makes it difficult to assign the appropriate driver to an lcs-device
or a ctcm-device. This patch eliminates the cu3088-driver and thus
the root device "cu3088". Path /sys/devices/cu3088 is replaced with
the pathes /sys/devices/lcs and /sys/devices/ctcm.
Patch is based on a proposal from Cornelia Huck.
Cc: Cornelia Huck <cornelia.huck@de.ibm.com>
Signed-off-by: Ursula Braun <ursula.braun@de.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
State transition to DEV_STATE_STOPPED indicates all outstanding I/O has
finished. Add wait queue to wait for this state.
Signed-off-by: Frank Blaschka <frank.blaschka@de.ibm.com>
Signed-off-by: Ursula Braun <ursula.braun@de.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
In a system where the ctrl-alt-del init action initiated by signal
quiesce suspends the machine the quiesce handler override for
_machine_restart, _machine_halt and _machine_power_off needs to be
undone, otherwise the override is still present in the resumed
system. The next shutdown would then load the quiesce state psw
instead of performing the correct shutdown action.
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
The monreader device driver doesn't set dev->driver_data to NULL after
freeing the corresponding data structure. This leads to a use after
free bug in the freeze/thaw suspend/resume functions after the device
has been opened and closed once. Fix this by clearing dev->driver_data
in the close() function.
Signed-off-by: Gerald Schaefer <gerald.schaefer@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
* git://git.kernel.org/pub/scm/linux/kernel/git/jejb/scsi-rc-fixes-2.6:
[SCSI] zfcp: Flush SCSI registration work when adding unit
[SCSI] zfcp: Fix timer initialization for ct and els requests
[SCSI] zfcp: Warn about storage devices with broken PLOGI data
[SCSI] zfcp: Handle WWPN mismatch in PLOGI payload
[SCSI] zfcp: fix kfree handling in zfcp_init_device_setup
[SCSI] fix memory leak in initialization
After copying uts->nodename to the static nodename array the static
version isn't necessarily zero termininated, since the size of the
array is one byte too short.
Afterwards doing strncat(data, nodename, strlen(nodename)); may copy
an arbitrary large amount of bytes.
Fix this by getting rid of the static array and using strncat with
proper length limit.
Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
Fix missing unregister_sysctl_table in case the SCLP doesn't provide
the requested feature. Also simplify the whole error handling while
at it.
Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
If a suspended z/VM guest has been logged off before the resume the
'SET SMSG IUCV' CP command need to be repeated to reenable sending
message via SMSG. This fixes the following error:
HCPMFS057I H4214002 not receiving; SMSG off
Error: non-zero CP response for command 'SMSG H4214002 CMM SHRINK 5010': #57
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
Fix the size of the local buffer and use snprintf to prevent
further miscalculations. Also fix the usage of bitwise vs logic
operations.
Signed-off-by: Sebastian Ott <sebott@linux.vnet.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
When configuring a LUN for use in zfcp, flush the SCSI work to ensure
the SCSI device has been created before returning. This means that a
configuration procedure can run these commands in a script and the
SCSI device is available immediately after the unit_add:
echo 1 > /sys/bus/ccw/drivers/zfcp/0.0.181d/online
echo 0x401040C300000000 > \
/sys/bus/ccw/drivers/zfcp/0.0.181d/0x500507630313c562/unit_add
lsscsi
Reviewed-by: Swen Schillig <swen@vnet.ibm.com>
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Add HZ since the start_timer function expects jiffies, not seconds.
Reviewed-by: Swen Schillig <swen@vnet.ibm.com>
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
After opening a remote port zfcp checks if the WWPN returned in the
PLOGI maches the WWPN of the port that should have been opened. On a
mismatch zfcp assumes that the DID just changed, queries the FC
nameserver and tries again. If the situation persists the erp will
give up.
With this strategy, if the remote port always returns the wrong PLOGI
data, the remote port will not be opened. Introduce a warning, so that
the system administrator knows why the remote port is not being opened
and to have a pointer to investigate the problem on the storage
system.
Reviewed-by: Swen Schillig <swen@vnet.ibm.com>
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
For ports, zfcp gets the DID from the FC nameserver and tries to open
the port. If the open succeeds, zfcp compares the WWPN from the
nameserver with the WWPN in the PLOGI payload. In case of a mismatch,
zfcp assumes that the DID of the port just changed and we opened the
wrong port. This means that zfcp has to forget the DID, lookup the DID
again and retry.
This error case had a problem that zfcp forgets the DID, but never
looks up a new one, stalling the ERP in this case. Fix this by
triggering the DID lookup and properly exit from the ERP. The DID
lookup will trigger a new ERP action.
Also ensure when trying to open the port again with the new DID, first
close the open port, even in the NOESC case.
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The pointer that is allocated with kmalloc() is passed to strsep()
which modifies it. Later on the modified pointer value will be passed
to kfree. Save the original pointer and pass that one to kfree
instead.
Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com>
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Group device now cleanly reacts to failures during channel start and
implements a clean rollback.
Signed-off-by: Einar Lueck <elelueck@de.ibm.com>
Signed-off-by: Ursula Braun <ursula.braun@de.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The creation of a new lcs device requires a call to the function
ccw_device_set_online() for the read and the write channel. Failure
of either call should terminate the lcs device creation immediately
with return code -ENODEV.
Signed-off-by: Klaus-Dieter Wacker <kdwacker@de.ibm.com>
Signed-off-by: Ursula Braun <ursula.braun@de.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Timer_list structure in lcs_send_lancmd() is allocated on stack.
Initialization with init_timer() leads to above ODEBUG message.
Instead use init_timer_on_stack() which prevents above msg.
Signed-off-by: Klaus-Dieter Wacker <kdwacker@de.ibm.com>
Signed-off-by: Ursula Braun <ursula.braun@de.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Fix this build error:
next-20091013 randconfig build on s390x build breaks with
drivers/s390/built-in.o:(.data+0x3354): undefined reference to `sclp_vt220_pm_event_fn'
Reported-by: Kamalesh Babulal <kamalesh@linux.vnet.ibm.com>
Signed-off-by: Michael Holzheu <michael.holzheu@linux.vnet.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
Use cio_is_console() in io_subchannel_probe to indicate that the
special handling is console specific. As long as there is no other
subchannel for which this might be true, it is misleading to speak
of "early devices". Should more of these devices be introduced,
a cleanup of all console special handling is in order anyway.
Signed-off-by: Peter Oberparleiter <peter.oberparleiter@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
8d65af78 "sysctl: remove "struct file *" argument of ->proc_handler"
removed the struct file argument from all proc_handlers but didn't
change the call home proc handler (or call home was merged later).
So fix this now.
Cc: Alexey Dobriyan <adobriyan@gmail.com>
Cc: Hans-Joachim Picht <hans@de.ibm.com>
Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
If the rdc_buffer is above 2G we need indirect addresssing so we have
to use an idaw to give the rdc_buffer to the ccw.
If the rdc_buffer is under 2G nothing changes.
Signed-off-by: Stefan Haberland <stefan.haberland@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
Replace spin_lock with spin_lock_irqsave in dasd_eckd_restore_device.
Signed-off-by: Stefan Haberland <stefan.haberland@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
When setting a channel attached tape online under Linux 2.6.31, the
"vol_id" process from udev hangs in sync_page():
2 sync_page+144 [0x1dfaac]
3 __wait_on_bit_lock+194 [0x58c23e]
4 __lock_page+116 [0x1df9dc]
5 truncate_inode_pages_range+728 [0x1ed7cc]
6 __blkdev_put+244 [0x25f738]
7 __fput+300 [0x229c4c]
8 filp_close+122 [0x225a3a]
The reason for that is an error in the request queue handling. It can
happen that we fetch a request, but do not process it further because
the number of queued requests exceeds TAPEBLOCK_MIN_REQUEUE.
To fix this, we should call blk_peek_request() instead of
blk_fetch_request() in the while condition and fetch the request in
the loop body afterwards.
This bug was introduced with the patch "block: implement and enforce
request peek/start/fetch" (9934c8c045)
Signed-off-by: Michael Holzheu <holzheu@linux.vnet.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
* git://git.kernel.org/pub/scm/linux/kernel/git/jejb/scsi-rc-fixes-2.6: (34 commits)
[SCSI] qla2xxx: Fix NULL ptr deref bug in fail path during queue create
[SCSI] st: fix possible memory use after free after MTSETBLK ioctl
[SCSI] be2iscsi: Moving to pci_pools v3
[SCSI] libiscsi: iscsi_session_setup to allow for private space
[SCSI] be2iscsi: add 10Gbps iSCSI - BladeEngine 2 driver
[SCSI] zfcp: Fix hang when offlining device with offline chpid
[SCSI] zfcp: Fix lockdep warning when offlining device with offline chpid
[SCSI] zfcp: Fix oops during shutdown of offline device
[SCSI] zfcp: Fix initial device and cfdc for delayed adapter allocation
[SCSI] zfcp: correctly initialize unchained requests
[SCSI] mpt2sas: Bump version 02.100.03.00
[SCSI] mpt2sas: Support dev remove when phy status is MPI2_EVENT_SAS_TOPO_PHYSTATUS_VACANT
[SCSI] mpt2sas: Timeout occurred within the HANDSHAKE logic while waiting on firmware to ACK.
[SCSI] mpt2sas: Call init_completion on a per request basis.
[SCSI] mpt2sas: Target Reset will be issued from Interrupt context.
[SCSI] mpt2sas: Added SCSIIO, Internal and high priority memory pools to support multiple TM
[SCSI] mpt2sas: Copyright change to 2009.
[SCSI] mpt2sas: Added mpi2_history.txt for MPI2 headers.
[SCSI] mpt2sas: Update driver to MPI2 REV K headers.
[SCSI] bfa: Brocade BFA FC SCSI driver
...
There is a race while re-reading the device characteristics. After
cleaning the memory area a cqr is build which reads the device
characteristics. This may take a rather long time and the device
characteristics structure is zero during this. Now it could be
possible that the block tasklet starts working and a new cqr will be
build. The build_cp command refers to the device characteristics
structure and this may lead into a divide by zero exception.
Fix this by re-reading the device characteristics into a temporary
structur and copy the data to the original structure. Also take the
ccwdev_lock.
Signed-off-by: Stefan Haberland <stefan.haberland@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
Improve the comments for switch cases without a break. This fixes
some warnings of a code checker tool.
Signed-off-by: Felix Beck <felix.beck@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
Allow users to set boxed devices offline. After setting them
offline, the device state will still be boxed.
Signed-off-by: Peter Oberparleiter <peter.oberparleiter@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
When a ccw device appears not operational, inform the associated
device driver and act according to the response: if the driver
wants to keep the device, put it into the disconnected state.
If not, or if there is no driver or if the device is not online,
unregister it. This approach is consistent with no-path event
handling.
Signed-off-by: Peter Oberparleiter <peter.oberparleiter@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
When there is no path left to a ccw device, inform the associated
device driver and act according to the response: if the driver
wants to keep the device, put it into the disconnected state.
If not, or if there is no driver or if the device is not online,
unregister it.
Signed-off-by: Peter Oberparleiter <peter.oberparleiter@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
There is a memory leak in /proc/cio_ignore. The iterator is allocated
in cio_ignore_proc_seq_start, but never freed in
cio_ignore_proc_seq_stop, because we cannot use the iterator
that was passed by seqfile. The seqfile interface passes the last
seen iterator to the stop function and not the first one. Since our
next function will return NULL at the end, the iter passed to
cio_ignore_proc_seq_stop is NULL. The original iter has leaked.
The solution is to use seq_open_private.
Found with kmemleak:
unreferenced object 0x1c720580 (size 32):
comm "head", pid 973, jiffies 4294958302
hex dump (first 32 bytes):
00 00 00 00 00 00 00 04 00 00 00 00 00 00 00 00 ................
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................
backtrace:
[<0000000000203154>] kmem_cache_alloc+0x190/0x19c
[<00000000003fb462>] cio_ignore_proc_seq_start+0x5e/0x128
[<0000000000231018>] seq_read+0xc8/0x4bc
[<0000000000273954>] proc_reg_read+0xa8/0xf4
[<000000000020e3d8>] vfs_read+0xac/0x1a4
[<000000000020e5c6>] SyS_read+0x52/0xa8
[<000000000011836e>] sysc_noemu+0x10/0x16
[<0000004690b7936c>] 0x4690b7936c
Signed-off-by: Christian Borntraeger <borntraeger@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
Move dev_set_name to when we know that the device will actually be
registered in order to avoid a memory leak if the allocated memory
for the channel path has to be freed.
Signed-off-by: Michael Ernst <mernst@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
Fix this build failure:
drivers/s390/built-in.o: In function `raw3270_pm_unfreeze':
(.text+0x3ac04): undefined reference to `ccw_device_force_console'
with:
CONFIG_TN3270=y
CONFIG_TN3270_CONSOLE=n
CONFIG_TN3215_CONSOLE=n
Reported-by: Kamalesh Babulal <kamalesh@linux.vnet.ibm.com>
Signed-off-by: Sebastian Ott <sebott@linux.vnet.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
This string query operation was supposed to be replaced by the
generic get_sset_count() starting in 2007. Convert qeth's
implementation.
Signed-off-by: Ben Hutchings <bhutchings@solarflare.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Running chchp --vary 0 and chccwdev -d on a FCP device with scsi
devices attached can lead to this thread hanging:
================================================================
STACK TRACE FOR TASK: 0x2fbfcc00 (kslowcrw)
STACK:
0 schedule+1136 [0x45f99c]
1 schedule_timeout+534 [0x46054e]
2 wait_for_common+374 [0x45f442]
3 blk_execute_rq+160 [0x217a2c]
4 scsi_execute+278 [0x26daf2]
5 scsi_execute_req+150 [0x26dc86]
6 sd_sync_cache+138 [0x28460a]
7 sd_shutdown+130 [0x28486a]
8 sd_remove+104 [0x284c84]
9 __device_release_driver+152 [0x257430]
10 device_release_driver+56 [0x2575c8]
11 bus_remove_device+214 [0x25672a]
12 device_del+352 [0x25456c]
13 __scsi_remove_device+108 [0x272630]
14 scsi_remove_device+66 [0x2726ba]
15 zfcp_ccw_remove+824 [0x335558]
16 ccw_device_remove+62 [0x2b3f2a]
17 __device_release_driver+152 [0x257430]
18 device_release_driver+56 [0x2575c8]
19 bus_remove_device+214 [0x25672a]
20 device_del+352 [0x25456c]
21 ccw_device_unregister+92 [0x2b48c4]
22 io_subchannel_remove+108 [0x2b4950]
23 css_remove+62 [0x2af7ee]
24 __device_release_driver+152 [0x257430]
25 device_release_driver+56 [0x2575c8]
26 bus_remove_device+214 [0x25672a]
27 device_del+352 [0x25456c]
28 device_unregister+38 [0x25464a]
29 css_sch_device_unregister+68 [0x2af97c]
30 ccw_device_call_sch_unregister+78 [0x2b581e]
31 worker_thread+604 [0x69eb0]
32 kthread+154 [0x6ff42]
33 kernel_thread_starter+6 [0x1c952]
================================================================
The problem is that the chchp --vary 0 leads to zfcp first calling
fc_remote_port_delete which blocks all scsi devices on the remote
port. Calling scsi_remove_device later lets the sd driver issue a
SYNCHRONIZE_CACHE command. This command stays on the "stopped" request
requeue because the SCSI device is blocked. Fix this by first removing
the scsi and fc hosts which removes all scsi devices and do not use
scsi_remove_device.
Reviewed-by: Felix Beck <felix.beck@de.ibm.com>
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
=======================================================
[ INFO: possible circular locking dependency detected ]
2.6.31-39.x.20090917-s390xdefault #1
-------------------------------------------------------
kslowcrw/83 is trying to acquire lock:
(&adapter->scan_work){+.+.+.}, at: [<0000000000169c5c>] __cancel_work_timer+0x64/0x3d4
but task is already holding lock:
(&zfcp_data.config_mutex){+.+.+.}, at: [<00000000004671ea>] zfcp_ccw_remove+0x66/0x384
which lock already depends on the new lock.
the existing dependency chain (in reverse order) is:
-> #1 (&zfcp_data.config_mutex){+.+.+.}:
[<0000000000189962>] __lock_acquire+0xe26/0x1834
[<000000000018a4b6>] lock_acquire+0x146/0x178
[<000000000058cb5a>] mutex_lock_nested+0x82/0x3ec
[<0000000000477170>] zfcp_fc_scan_ports+0x3ec/0x728
[<0000000000168e34>] worker_thread+0x278/0x3a8
[<000000000016ff08>] kthread+0x9c/0xa4
[<0000000000109ebe>] kernel_thread_starter+0x6/0xc
[<0000000000109eb8>] kernel_thread_starter+0x0/0xc
-> #0 (&adapter->scan_work){+.+.+.}:
[<0000000000189e60>] __lock_acquire+0x1324/0x1834
[<000000000018a4b6>] lock_acquire+0x146/0x178
[<0000000000169c9a>] __cancel_work_timer+0xa2/0x3d4
[<0000000000465cb2>] zfcp_adapter_dequeue+0x32/0x14c
[<00000000004673e4>] zfcp_ccw_remove+0x260/0x384
[<00000000004250f6>] ccw_device_remove+0x42/0x1ac
[<00000000003cb6be>] __device_release_driver+0x9a/0x10c
[<00000000003cb856>] device_release_driver+0x3a/0x4c
[<00000000003ca94c>] bus_remove_device+0xcc/0x114
[<00000000003c8506>] device_del+0x162/0x21c
[<0000000000425ff2>] ccw_device_unregister+0x5e/0x7c
[<000000000042607e>] io_subchannel_remove+0x6e/0x9c
[<000000000041ff9a>] css_remove+0x3e/0x7c
[<00000000003cb6be>] __device_release_driver+0x9a/0x10c
[<00000000003cb856>] device_release_driver+0x3a/0x4c
[<00000000003ca94c>] bus_remove_device+0xcc/0x114
[<00000000003c8506>] device_del+0x162/0x21c
[<00000000003c85e8>] device_unregister+0x28/0x38
[<0000000000420152>] css_sch_device_unregister+0x46/0x58
[<00000000004276a6>] io_subchannel_sch_event+0x28e/0x794
[<0000000000420442>] css_evaluate_known_subchannel+0x46/0xd0
[<0000000000420ebc>] slow_eval_known_fn+0x88/0xa0
[<00000000003caffa>] bus_for_each_dev+0x7e/0xd0
[<000000000042188c>] for_each_subchannel_staged+0x6c/0xd4
[<0000000000421a00>] css_slow_path_func+0x54/0xd8
[<0000000000168e34>] worker_thread+0x278/0x3a8
[<000000000016ff08>] kthread+0x9c/0xa4
[<0000000000109ebe>] kernel_thread_starter+0x6/0xc
[<0000000000109eb8>] kernel_thread_starter+0x0/0xc
cancel_work_sync is called while holding the config_mutex. But the
work that is being cancelled or flushed also uses the config_mutex.
Fix the resulting deadlock possibility by calling cancel_work_sync
earlier without holding the mutex. The best place to do is is after
offlining the device. No new port scan work will be scheduled for the
offline device, so this is a safe place to call cancel_work_sync.
Reviewed-by: Felix Beck <felix.beck@de.ibm.com>
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
With the change that the zfcp_adapter struct is only allocated when
the device is set online, the shutdown handler has to check for a
non-existing zfcp_adapter struct. On the other hand, this check is not
necessary in the offline callback, since an online device has the
zfcp_adapter allocated and we go through the offline callback before
removing the ccw device.
Reviewed-by: Felix Beck <felix.beck@de.ibm.com>
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
With the change for delaying the allocation of zfcp_adapter, the
initial device parameter function has to first call
ccw_device_set_online which allocates the zfcp_adapter structure.
Change this and adapt the cfdc part accordingly.
Reviewed-by: Felix Beck <felix.beck@de.ibm.com>
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The common initialization of ct/gs and els requests missed the
initialization of unchained requests. Fix this by moving the common
parts to a place that is called for all ct/gs and els requests.
Reviewed-by: Felix Beck <felix.beck@de.ibm.com>
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>