'default n' is the default value for any bool or tristate Kconfig
setting so there is no need to write it explicitly.
Also since commit f467c5640c ("kconfig: only write '# CONFIG_FOO
is not set' for visible symbols") the Kconfig behavior is the same
regardless of 'default n' being present or not:
...
One side effect of (and the main motivation for) this change is making
the following two definitions behave exactly the same:
config FOO
bool
config FOO
bool
default n
With this change, neither of these will generate a
'# CONFIG_FOO is not set' line (assuming FOO isn't selected/implied).
That might make it clearer to people that a bare 'default n' is
redundant.
...
Signed-off-by: Bartlomiej Zolnierkiewicz <b.zolnierkie@samsung.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
This patch adds support for LTM4686 Ultrathin Dual 10A or
Single 20A uModule Regulator with Digital Power System Management.
Datasheet: http://www.analog.com/ltm4686
Signed-off-by: Michael Hennerich <michael.hennerich@analog.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
MAX34451 is a 16-Channel Voltage/Current Monitor and 12-Channel
Sequencer.
Signed-off-by: Kun Yi <kunyi@google.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Building without CONFIG_LEDS_CLASS causes a link failure:
drivers/hwmon/pmbus/ibm-cffps.o: In function `ibm_cffps_probe':
ibm-cffps.c:(.text+0x4f4): undefined reference to `devm_of_led_classdev_register'
This adds the required dependency.
Fixes: ef9e1cdf41 ("hwmon: (pmbus/cffps) Add led class device ...")
Signed-off-by: Arnd Bergmann <arnd@arndb.de>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
The Maxim MAX31785 is a PMBus device providing closed-loop, multi-channel
fan management with temperature and remote voltage sensing. It supports
various fan control features, including PWM frequency control, temperature
hysteresis, dual tachometer measurements, and fan health monitoring.
This patch presents a basic driver using only the existing features of the
PMBus subsystem.
Signed-off-by: Andrew Jeffery <andrew@aj.id.au>
[groeck: Modified description to clarify that fan control is not yet provided]
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Add the driver to monitor IBM CFF power supplies with hwmon over
pmbus.
Signed-off-by: Edward A. James <eajames@us.ibm.com>
[groeck: drop 'default n'; include bitops.h instead of jiffies.h]
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
IR35221 is a Digital DC-DC Multiphase Converter
Signed-off-by: Samuel Mendoza-Jonas <sam@mendozajonas.com>
[groeck: Preserve alphabetic order in Kconfig;
add missing break statements (from Dan Carpenter);
add missing error checks]
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
The UCD90160 Power Supply Sequencer reuses the existing register layout,
so just an id addition was required.
Signed-off-by: Matthew Weber <matthew.weber@rockwellcollins.com>
Signed-off-by: Ronak Desai <ronak.desai@rockwellcollins.com>
[groeck: Updated description, ordered alphabetically, added documentation]
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
ADM1278 is mostly compatible to other chips of the same series.
Besides the usual difference in coefficients, it supports
a temperature sensor, and it can measure both input and output
voltage at the same time.
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
LTC3815 is a Monolithic Synchronous DC/DC Step-Down Converter.
Cc: Michael Jones <mike@proclivis.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
LTC3886 is a is a dual PolyPhase DC/DC synchronous step-down switching
regulator controller. It is mostly command compatible to LTC3883,
but supports two phases instead of one.
Suggested-by: Michael Jones <mike@proclivis.com>
Tested-by: Michael Jones <mike@proclivis.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
LTC2980 and LTM2987 are command compatible to LTC2977. They consist of
two LTC2977 on a single die, and are instantiated as two separate chips,
each supporting eight channels.
Suggested-by: Michael Jones <mike@proclivis.com>
Tested-by: Michael Jones <mike@proclivis.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
LTC2975 is mostly compatible to LTC2974, but supports input current
and power measurement.
Tested-by: Michael Jones <mike@proclivis.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Add device IDs and references for Texas Instruments TPS544B20, TPS544B25,
TPS544C20, and TPS544C25 to the generic PMBus driver.
Reviewed-by: Jean Delvare <jdelvare@suse.de>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
MAX20751 is a multiphase power controller with internal buck converter.
It uses VR12.0 to report the output voltage. This requires an explicit
driver, since the VR version can not be auto-detected.
The chip supports a manufacturer specific command to fine-tune the output
voltage. This command is not currently supported.
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
ADM1293 and ADM1294 are mostly compatible with other chips of the same
series, but have more configuration options. There are also some
differences in register details.
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Support for keyword 'boolean' will be dropped later on.
No functional change.
Reference: http://lkml.kernel.org/r/cover.1418003065.git.cj@linux.com
Signed-off-by: Christoph Jaeger <cj@linux.com>
Signed-off-by: Michal Marek <mmarek@suse.cz>
Add simple on/off regulator support for ltc2978 and
other pmbus parts supported by the ltc2978 driver.
Signed-off-by: Alan Tull <atull@opensource.altera.com>
Cc: Guenter Roeck <linux@roeck-us.net>
Cc: Mark Brown <broonie@kernel.org>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
For TI power management chip TPS40422, READ_TEMPERATURE_2 command is supported on
page 1 of the chip, but the original driver(pmbus.c) only tried to detect this command
on page 0, this will lead to a result that the temperature sensor in page 1 couldn't
be detected. This change is to isolate the tps40422 driver from pmbus.c into a solo
front-end driver.
Signed-off-by: Zhu Laiwen <richard.zhu@nsn.com>
[Guenter Roeck: Dropped unnecessary license text (fixes checkpatch warning)]
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
MAX34460 is a PMBus 12-Channel Voltage Monitor & Sequencer.
MAX34461 is a PMBus 16-Channel Voltage Monitor & Sequencer.
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
This config item has not carried much meaning for a while now and is
almost always enabled by default. As agreed during the Linux kernel
summit, remove it.
CC: Guenter Roeck <linux@roeck-us.net>
CC: Jean Delvare <khali@linux-fr.org>
Signed-off-by: Kees Cook <keescook@chromium.org>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
ZL9101M and ZL9117M are compatible to ZL6100. Add support to the zl6100 driver.
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Acked-by: Jean Delvare <khali@linux-fr.org>
MDT040 is supported by the generic PMBus driver. Add device ID and reference to
datasheet. Also mention Lineage Power device support in Kconfig.
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
TPS40400 and TPS40422 are supported by the generic PMBus driver.
Add device IDs and data sheet references.
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Add support for Ericsson BMR450, BMR451, BMR462, BMR463, and BMR464, which are
based on ZL2005 and ZL2008, to zl6100 driver. Remove BMR450 and BMR451 device
IDs from generic PMBus driver.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
Add explicit support for ZL2005. Functionality is almost the same as with other
Zilker Labs / Intersil chips, but limit register detection does not work reliably.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
The LTC3880 PMBus command set is comparable to LTC2978. Add support for it
to the LTC2978 driver.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
Provide explicit driver for LTC2978 to enable support for minimum and peak
attributes. Remove ltc2978 chip id from generic pmbus driver.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
ADM1276 is mostly compatible to ADM1275, with added support for input power
measurement. Add support for it to the ADM1275 driver.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Acked-by: Jean Delvare <khali@linux-fr.org>
Add ADP4000, NCP4200 and NCP4208 to the list of devices supported by the generic
PMBus driver, and add device IDs to enable explicit instantiation.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
Acked-by: Jean Delvare <khali@linux-fr.org>
Since the number of PMBus drivers is getting large, move them into
directory drivers/hwmon/pmbus to improve readability and scalability.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>